VENTING
INSTALLATION

Continued

(Framing

Detail)

10"

(254mm)

10"

(254mm)

7

1

/

2

"

(190mm)

Vent Opening

Combustible Wall

Vent Opening

Noncombustible Wall

Figure 12 - Vent Opening Requirements

Continued

3.

Attach vent pipe assembly to the fire-
place. Set fireplace in front of it’s per-
manent location to insure minimum
clearances. Mark the wall for a 10"
square hole (for noncombustible mate-
rial such as masonry block or concrete,
a 7

1

/

2

" diameter hole is acceptable). See

Figure 12. The center of the hole should
line up with the center-line of the hori-
zontal rigid vent pipe. Cut a 10"x10"
(254mm x 254mm) square hole through
combustible exterior wall (7

1

/

2

"

[190mm] diameter hole if noncombus-
tible). Frame as necessary (see Figure
12).

UP

Figure 14 - Installing Vinyl Siding Standoff

Cut Vinyl Siding
Away to Fit
Standoff

Wood Screw

Nut

Bolt

Standoff

Vent Cap

Figure 11 - Vent Pipe Connections

Female
Locking
Lugs

Male
Slots

Rigid Vent Pipe Flexible Vent Pipe

Spacer
Spring

4" Clamp

7" Clamp

4" Flex
Pipe

7" Flex
Pipe

Apply Mastic
to All Four Sides

Figure 13 - Installing Horizontal Vent Cap

UP

Wood
Screw

Vent Cap

Apply Mastic
to All Four
Sides

WARNING: Do not recess vent

termination in to any wall. This
will cause a fire hazard.

4.

Apply a bead of non-hardening mastic
around the outside edge of the vent cap.
Position the vent cap in the center of
the 7

1

/

2

" or 10" hole on the exterior

wall with the arrow on the vent cap
pointing up. Insure proper clearance of
1" to combustibles is maintained. At-
tach the vent cap with four wood screws
supplied (see Figure 13).

Note

: Re-

place the wood screws with appropri-
ate fasteners for stucco, brick, concrete,
or other types of siding.

For vinyl siding use vinyl siding stand-
offs between vent cap and exterior wall.
The vinyl siding standoff prevents ex-
cessive heat from melting the vinyl sid-
ing material. Bolt the vent cap to the
standoff. Apply non-hardening mastic
around outside edge of the standoff in-
stead of the vent cap assembly. Use
wood screws provided to attach the
standoff. See Figure 14.

5.

Slide the wall thimble over the vent pipe
before connecting the horizontal run to
the vent cap (see Figure 15).

6.

Carefully move the fireplace with vent
assembly attached toward the wall and
insert the vent pipe into the horizontal
termination. The pipe overlap should
be a minimum of 1

1

/

4

". Apply silicone

to the outer pipe connection. Fasten all
vent connections with screws provided.
Refer to Fireplace Installation on page
16 for instructions on securing unit to
framing or floor.

7.

Slide the wall thimble against the inte-
rior wall surface and attach with screws
provided (see Figure 15).

Vent Cap
(Horizontal
Termination)

Interior Wall
Surface

Wall
Thimble

Horizontal
Vent Pipe

Figure 15 - Connecting Vent Cap with
Horizontal Vent Pipe

Screw