5.4.2
Draining the collecting container
The collecting container must be drained after the expansion relief valve
has been triggered.
•
Make sure that the solar fluid has cooled down before you drain the
collecting container.
•
Remove the safety cap from the expansion relief valve.
•
Drain the collecting container into a vessel that is suitable for solar
fluid.
•
Dispose of the removed solar fluid correctly.
5.5
Maintenance
•
At least once a year, check that the collecting container's basic filling
level (1 litre) is correct.
5.6
Notes on the piping system
a
DANGER:
Risk of personal injury and material damage due to escaping
hot solar fluid!
Hot solar fluid can damage plastic pipes and consequently
escape.
- Use copper pipes.
Caution:
Press fittings that are not temperature resistant may damage
the solar energy system! Press fittings must be designed for
temperatures up to 200
o
C - otherwise, the press fittings may
start to leak.
- Ask the manufacturer of the press fittings whether the press
fittings are solar resistant.
6
Handing over to the operator
You must inform the operator of the unit about the handling and function
of their collecting container.
•
Provide the operator with all relevant instructions and unit
documentation for safe-keeping.
•
Go through the operating instructions with the operator.
•
Answer any questions the operator may have.
•
Draw special attention to the safety information which the operator
must follow.
•
Inform the operator of the necessity to ensure that the system
is regularly inspected/maintained (inspection and maintenance
contract).
•
Make the operator aware of the need to keep the instructions near the
collecting container.
7
Customer service
Servicing/maintenance should be carried out by a competent person
approved at the time by the Health and Safety Executive in accordance
with the rules in force in the countries of destination.
To obtain service, please call your installer or Glow-worm's own service
organisation on Tel: 01773 828100.