beautypg.com

2 technical data, 1 identification plate, 2 buffer vessel – Glow-worm Clearly Heat Pump - Buffer Vessel User Manual

Page 8: 3 technical data 2.4 safety valves

background image

8

2 Technical Data

2.1 Identification plate

The identification plate is fitted on the side of the outer

casing, please quote reference numbers when ordering spare

parts

2.2 Buffer vessel

The buffers are primarily intended for internal use.

The buffer vessel is available in two sizes

180 and 60l nominal capacity.

2.3 Technical Data

2.4 Safety valves

NOTE: These buffers are fitted with pressure relief valves as

standard, which are positioned within the casing and will have

to be connected to a suitable drain point where the units are

fitted indoors.

Description

Units

60 litre

180 litre

Overall height

mm

330

1284

Overall length

mm

1190

754

Overall depth

mm

500

633

Weight, unfilled

kg

53

95

Weight, filled

kg

110

275

Vessel capacity

l

60

180

Permissible operating pressure

bar

3.0

3.0

Max. permissible temperature

°C

95

95

Connection sizes (series)

inches

2 x 1¼M

2 x 2”M

Connection sizes (parallel)

Inches

2 x 1½ M

2 x 2½” M

Packaged dimensions

mm

1198 x 568 x 486(h)

715 x 765 x 1419(h)

Packaged Weight

kg

65

106