Setup Maintenance

Continued

Changing the Current Setup

Try using your navigation skills on this example:
1. Follow instructions on Page 24 to set the mode to

Weld by Time. Set the time to 1.520 seconds.

See Figure 5-20.

2. Press SETUP, and you will notice that the time

just set appears in the current setup.The new time
replaced whatever time was in the current setup. It
was changed, or overwritten.

3. To avoid having your current setup changed: Press

SETUP, and with LOAD highlighted, use the
keys to select an empty setup. Press ENTER.

Then, make the Time (and/or Energy) entries. Nothing
will be overwritten because your entries were made
in an empty setup.

4. Confirm that your setup has been saved in memory

by going back to SETUP. Your new setup should
appear, as it does in Figure 5-22.

Selecting a Setup

To select a setup previously loaded:

1. Press SETUP.

2. With Load highlighted, use the keys to select

the number of the setup you want.

3. Press ENTER.

4. The Operate screen will display this setup selection

as a number in the display’s lower left hand corner.

Deleting a Setup

To delete a setup previously stored:

1. Press SETUP.

2. With Delete highlighted, use the keys to select

the number of the setup you want.

3. Press ENTER, and a pop-up screen will ask you to

confirm your selection. Make your choice, and press
ENTER.

4. Check that the setup is deleted. Press SETUP, and

the Setup Maintenance screen will show EMPTY for
the setup you just deleted.

Figure 5-20 Set Time

Figure 5-21 New Setup Saved

Setup Maintenance

Setup #

1

T: 1.520 S A: 100%

Mode: Automa

tion

E: 0 J H: 0.0 S

Delete

TBP: OFF

Load

Weld by Time

Press Enter To Accept
Press Cancel To Abort

Weld Time

1.520 S

+ -

+ -

+ -

NOTE

The power supply program always has
one default setup (as shown below).
This can be overwritten, but can not be
deleted.

Setup Maintenance

Setup #

1

T: 0.000 S A: 100%

Mode: Manual

E: 0 J H: 0.0 S

Delete

TBP: OFF

Load

Figure 5-22 Default Setup Screen