Section 5 - Process Control Settings

Dukane Manual Part No. 403-583-00

System Information,

Advanced Settings

When the INFO key is pressed the display looks like
Figure 5-11:
Using the keys, move the pointer to indicate:

System Information, or

Advanced Settings

Press ENTER to make the selection.

1.

System Information

Manufacturer’s information is shown including the
manufacturer’s name, the name of the system, and the
software identification.

Figure 5-11A shows an example of this information.

iQ Information

> System Information

Advanced Settings

Figure 5-11 INFO Screen

+ -

Figure 5-11A System Information Example Screen

Dukane Corporation
iQ AL Series 40kHz
FP v1.08 MB v2.56
FPGA v7

Continued

2.

Advanced Settings

After Advanced Settings is selected, a warning
screen is displayed as shown in Figure 5-12.

Adjusting these settings may affect the operation of
your unit. Before you change a setting, please check
with Dukane personnel for their recommendations.

The warning screen is shown for a few seconds, then,
the Advanced Settings screen appears.

See Figure 5-13.

Adjustments can be made to:

Free Run Frequency

;

Ramp Up Time

;

Frequency Lock and Hold

; a n d ,

Trigger By Power

, but note that

Trigger by Power

is only available when the weld mode is Time or
Energy.

Free Run Frequency

Free Run is the frequency at which the generator
drives the ultrasound output pulses until a valid
resonant frequency feedback signal is detected.
Typically this value should be below the operating
frequency of the probe.

Follow the on screen prompts to make setting adjust-
ments.

NOTE

Trigger by Power is only avail-
able when the weld mode is
either Time or Energy.

Figure 5-12 Warning Screen

Warning

Modified settings

may affect operation

of this unit!

Figure 5-13 Advanced Settings Screen

Advanced Settings

>

Trigger By Power

ON

OFF

Press Enter To Accept

Press Cancel To Abort

Lock and Hold

ON

OFF

Ramp Up Time

Free Run Freq

19900Hz

150mS