Lockout/Tagout
Procedure to use BEFORE making any internal
adjustments to the generator:
1.
Push the generator's AC power switch/
breaker to the OFF position.
2.
Unplug the generator's electrical cord from
its source.
3.
Authorized personnel apply a lockout/
tagout (LOTO) device to the plug end of the
generator's electrical cord. Using a typical
clam shell type LOTO device:
1) Open the clam shell.
2) Place the electrical cord plug end
inside the shell.
3) Close the shell.
4) Secure the shell with its lock, and
lock it.
4.
Wait a minimum of five minutes for the
generator to discharge its electrical energy.
5.
After taking these steps, make the necessary
adjustments to the generator.
Assuming the generator is being put back into
service. . .
Procedure to use AFTER making any internal
adjustments to the generator:
1. Authorized personnel remove the lockout/
tagout device from the plug end of the
generator's electrical cord. Using a typical clam
shell type LOTO device:
1) Unlock the protective shell.
2) Open the shell, exposing the electrical
cord end.
3) Remove the LOTO device, and set it
aside.
2. Plug the generator's electrical cord into its AC
power source.
3. Push the generator's AC power switch/breaker
to the ON position.