Basic System Components

Shown below is a typical basic ProAnnounce equipment list of the ProAnnounce components for
a 4 zone BGM installation. This list includes a basic paging station and the ability to connect any
number of remote volume controls on the system. The design can accept up to 3 different BGM
sources to assign to any zone. The total power amplification of this design example is 400 watts.

Model

Description

DPM4000PA

Central Unit Matrix System Processor

NRS90228

121680

Input Module: 2 Channel Aux (RCA Phono Connectors)

NRS90234

121736

Input Module: Combination Mic/Line + Paging Console

NRS90218

121668

2 Channel Output Line Module

DPC4510

121623

8 Function/10 Selection Key Paging Console, with Display

DCS400

121773

19" Mounting Frame for DCS Modules

DCS401R

121774

Controller Module

DCS412R

121780

Logic Input Module

DCS416R

121782

Analog I/O Module

DPA4410PA

121793

ProAnnounce Series 4 Channel Power Amplifier 4x100w

Audio Routing Made Easy

The DPM 4000 employs a digital audio matrix providing 4 inputs and 4 outputs. Additional matrix
junctions for the integrated gong and alarm signal generators, the vocal recording/playback unit,
and the lock-on of the pilot tone and its evaluation are incorporated. All input signals and
internally generated signals can be freely mixed inside the matrix and outputted through the 4
amplifier channels. Routing speaker lines to these amplifier channels is achieved via the relay-
matrix, which offers up to four separate audio buses simultaneously, while the DPM 4000 takes
over the management of all these signals according to their priority.

Next to connecting paging stations, the audio inputs also serve for the connection of other audio
sound sources, like microphones, mixers, CD-players, cassette decks and DAT-recorders, tuners,
etc. Several different input modules are available to optimally adjust and match signal levels and
connections.

Other additional features include the DMM4650 message manager for prerecorded
announcements, digitally controlled paging stations for extensive system control, DCS monitoring
and control system for external system control of many functions.

ProAnnounce DP Series Power Amplifiers

The DP series amplifiers includes four models, offering common features as listed below:

3 models: DPA 4410 (4 x 100 W), DPA 4411 (4 x 100 W) with remote control,
DPA 4260 (2 x 600 W).

Floating 70V power outputs (internally configurable to 100v, 70v or 4

Ω)

Outputs are protected against idling and short-circuit

Operation at 115/230 V AC and 24 V DC (emergency power supply)

AC and battery remote on/off

Electronically balanced inputs, transformers are optionally available.

Input level controls

Monitor outputs

Temperature-controlled operation

Pilot tone and ground fault surveillance (optionally available)

Fault indication and fault messaging via floating READY-contact

ElectroVoice/Dynacord BGM Guide