FeiYu Tech FY-ARHS-1200A User Manual
Page 11

GuiLin FeiYu Electronic Technology Co., Ltd
GuiLin FeiYu Electronic Technology Co., Ltd http://www.feiyudz.cn E-mail: [email protected]
Page 10
4,38400
5,56000
6,57600
7,115200
Configure
magnetic
declination
$Config
4
Setting of the
magnetic
declination,
Parameter setting
range
-360 — 360
For setting the
magnetic
deviation angle
and installed
heading bias
NULL
NULL
NULL
Open/Close the
FY-AHRS-1200A
serial data
output
$Config
9
Parameter setting
range
0 — 1
0,close
1,open
NULL
NULL
NULL
Command
type
Command
head
Command
NO
Parameter
1
Parameter
2
parameter
3
parameter
4
magnetic field
calibration
$Config
10
The magnetic
field calibration
options
1 — 2
1,Start calibration
XY-axis magnetic
field
2,Reserved.
After send this
command, must
clockwise rotate
FY-AHRS-1200A
horizontally to
complete the
magnetic field
calibration
NULL
NULL
NULL
write the
configuration
information
in the FLASH
$Config
99
Is fixed at 1
Once configured,
send this
command to write
NULL
NULL
NULL