beautypg.com

Dukane 8064 User Manual

Page 44

background image

42

Lamp (continued)
When the indicators or a message prompts you to replace the lamp, replace the

lamp as soon as possible.

1.

Turn the projector off, and unplug the power cord. Allow the lamp to cool for

at least 45 minutes.

2.

To prepare a new lamp, contact your dealer and tell the lamp type number

=

DT00701. If the projector is mounted on the ceiling, or if the lamp has

broken, also ask the dealer to replace the lamp.

In the case of replacement by yourself,

3.

After making sure that the projector has cooled

adequately, slowly turn over the projector, so

that the bottom is facing up.

4.

Please unhook the claws of the lamp cover using a

minus screwdriver or similar, and remove the lamp

cover.

5.

Loosen the 2 screws (marked by arrow) of the lamp,

and slowly pick up the lamp by the

handles.

6.

Insert the new lamp, and retighten

firmly two screws that are loosened

in the previous process to lock it in

place.

7.

Interlocking the 2 tabs of the lamp

cover to the projector, position the

lamp cover on the projector. Then push the

center point of two claws to fix the lamp cover.

8.

Slowly turn the projector so that the top is

facing up.

9.

Turn the projector on, and reset the lamp time

using the LAMP TIME function of OPTION

menu (39).

NOTE • When the lamp has been replaced after the message of "THE

POWER WILL TURN OFF AFTER 0hr." is displayed, complete the following

operation within 10 minutes of switching power on.

• Incorrectly resetting of the lamp timer (resetting without replacement, or

neglect of resetting after replacement) will result in incorrect message functions.

Maintenance

Claws of lamp cover

Tabs

Screws marked

by arrow

Center

point

of claws