beautypg.com

P75 mk3 jumper location and settings – Dynavector P-75 MK3 User Manual

Page 2

background image

All the above adjustments are easily made by the user. No soldering or extra
components are required.

Standard Settings

When delivered from the factory, the P75 is set to the following standard settings:
Low output moving coil

100 ohm

63dB gain. Shown above.

www.dynavector.com.au

Designed and manufactured in Australia by

Dynavector Amplifiers Australia

P75 mk3 Jumper Location and Settings

Normal (40dB)

High (46dB)

1mV Cartridge

High output MC or Moving Magnet and special 1mV MC

Low output MC ­ standard phono mode

Normal (60dB)

470 Ω

220 Ω

100 Ω

60 Ω

30 Ω

Phono Enhancer mode (Low output MC)

JB 3 & 4

Output level

Set jumpers to suit coil resistance*

Phono Enhancer mode notes
* The coil resistance is obtained from the cartridge manufacturer's specifications.
This resistance is the DC resistance of the coil, sometimes referred to as the
impedance. It is not the cartridge loading resistance.

An example may help:
Dynavector's DV XX2 mkII specification sheet gives the following:

Impedance

R = 6 Ω (ohms)

Recommended load resistance

>30 Ω. Ignore this in PE Mode.

The DC coil resistance for the DV­XX2 mkII is 6 ohms therefore in PE mode, set
JB3 & 4 for a low resistance coil.

See www.dynavector.com for complete Dynavector cartridge specifications.

For more information visit www.dynavector.com.au

Medium resistance

approx 10­20Ω

Low resistance

approx 4­10Ω

High resistance

approx 20­50Ω

Key

blank = no jumper

= fit jumper

= no effect, jumper may be fitted or left off

JB7 & 8

Gain setting

JB3 & 4

Gain setting

High (63dB)

JB1 & 2

Cartridge loading

In appreciation

We wish to express our great appreciation to the late Mr John Bevan
Ford of New Zealand­Aotearoa, contemporary Maori artist and music
devotee, for his generous assistance with the appearance and
functional design of our Dynavector products. While his insight will be
sorely missed, we shall continue to follow his clear guiding principles.

Haere ra John.

© Dynavector Systems Australia Pty Ltd 2012

P75 mk3 manual rev 1.0 PDF version