Press the button (see item 6 on the control panel display)
for 5 seconds again to exit parallel curve adjustment mode.
If the room temperature is lower lower than the required
value, it is advisable to set a higher order curve and vice
versa. Proceed by increasing or decreasing in steps of one
and check the result in the room.
Compensation curves
Heating Temperature Adjustment Adjustment can be made from the boiler control panel.
Domestic Hot Water Temperature Adjustment can be made from the boiler control panel.
Summer/Winter Switchover
Summer mode has priority over a possible heating demand.
Eco/Comfort Selection
On disabling DHW from the menu, the boiler selects the Economy mode. In this condition, the
button 7 from control panel display is disabled.
On enabling DHW from menu, the boiler selects the Comfort mode. In this condition it is
possible to select on of the two modes with the button 7 from control panel display.
Sliding Temperature
Boiler card manages Sliding Temperature adjustment: the boiler card Sliding
Temperature has priority.
10 - OPERATING INSTRUCTIONS
30