beautypg.com

Dunkirk WPSB Series II User Manual

Page 22

background image

22

OPERATING THE BOILER - SYSTEM START-UP

Table 1 - Troubleshooting

Burner Will Not Fire

No or Insuffi cient Domestic

Hot Water

If installed with indirect water heater, insure end switch in relay box controlling indirect water

heater is properly connected to cable 2 (see wiring diagram). This insures domestic water calls

are prioritized. If cable 2 is not used, turn Economy Feature OFF.

House will not get or stay

warm

1.

Check for air bound radiators.

2.

Check thermostat settings including heat anticipator settings (common on non-digital

thermostats.

3.

Check Economy settings. Economy feature, much like outdoor reset controls, lowers

average boiler temperature, can slow or prevent the house from coming up to

temperature. Move to lower setting.