Information menu – Clay Paky SHARPY User Manual
Page 20

20
SHARPY
Used for restoring default values on all options menu items and relevant submenus.
1) Press
F
, a confirmation message (Are you sure?) appears on the display.
2) Select YES to confirm the selction or NO to keep current setting.
OPTION
DEFAULT
Lamp DMX
On
Safety Black Out
Off
Invert Pan
Off
Invert Tilt
Off
Swap Pan-Tilt
Off
Encoder Pan-Tilt
On
P/T Homing Mode
Standard
Pan Home Def Pos
270 degrees
Tilt Home Def Pos
50%
Fixed Wheel Shortcut
On
Linear Movement
Off
Shutter on error
Off
Dimmer Filter Type
DMX follower
Display
On
SYSTEM ERRORS
Shows a list of warnings and messages relevant to errors occurred since
the fixtures switching-on.
1) Pressing
F
you are allowed to reset the SYSTEM ERRORS list.
A confirmation message (Are you sure you want to clear error list ?)
appears on the display.
2) Select YES to reset the list or NO to go back.
FIXTURE HOURS
Used for displaying projector operating hours (total and partial).
1) Press
F
- Hours total and partial appears on the display.
Total counter
Counts the number of projector working life hours (from manufacture to date).
Partial counter
Counts the number of partial projector working life hours since the last
reset to date.
2) Press
F
to reset partial projector working hours a confirmation
message (Are you sure?) appears on the display.
3) Select YES to reset partial projectors counter or NO to keep the current
setting and return to the top menu level.
LAMP HOURS
Used for displaying the lamp working hours (total and partial).
1) Press
F
- Hours total and partial appears on the display.
Total counter
Counts the number of projector working hours with the lamp on (from
manufacture to date).
Partial counter
Counts the number of lamp working hours since the last reset to date.
2) Press
F
to reset partial lamp working hours, a confirmation message
(Are you sure ?) appears on the display.
3) Select YES to reset partial counter or NO to keep the current setting
and return to the top menu level
LAMP STRIKES
Used for displaying the number of times the lamp was turned on (total and
partial).
1) Press
F
- the number of times the lamp was turned on (total and
partial) appears on the display.
Total counter
Counts the number of times the lamp was turned on (from manufacture
to date).
Partial counter
Counts the number of times the lamp was turned on since the last reset
to date.
2) Press
F
to reset partial lamp strikes hours, a confirmation message
(Are you sure ?) appears on the display.
3) Select YES to reset partial counter or NO to keep the current setting
and return to the top menu level
Lamp
Strikes
Total
XXX
Partial XXX
Reset...
Lamp
Hours
Total
XXX
Partial XXX
Reset...
INFORMATION MENU
Information
System
Errors
Fixture
Hours
Total
XXX
Partial XXX
Reset...
Option
Setting