Operating fireplace – Desa (V)T36NA User Manual
Page 29

www.desatech.com
111250-01E
29
4. Press the POWER and LOCK buttons
together to turn off the fireplace
Note:
Do not leave the hand-held remote in
the AUTO mode close to the fireplace. The
radiant heat from the fireplace will turn off the
fireplace. Ideally, place the hand-held remote
in the center of the room facing towards the
fireplace.
Note:
Do not hold the hand-held remote for
a long time. Body temperature will affect its
operation in the AUTO mode.
Safety Features
When away from home for an extended period
of time or as a child safety feature to prevent
accidental ignition of the fireplace, the receiver
ON/OFF/REMOTE switch should be in the
OFF position.
Auto Shutoff Feature
1. If the average room temperature exceeds
82° F (28° C), the hand-held remote control
will perform a safety override and shut the
fireplace off. This feature is not available in
the MANU mode.
2. The receiver continuously receives signals
from the hand-held remote to control the
room temperature. If the hand-held remote
is misplaced, obstructed or for any reason
cannot transmit to the receiver, the receiver
will shut off the fireplace after 8 minutes.
OPERATING FIREPLACE
Continued
OpERATING OpTIONAL
GWMT1 WALL MOUNTED
THERMOSTAT
WARNING: Do not con-
nect the thermostat to a power
source. Electrical shock and/or
a fire hazard will occur.
Light the fireplace as instructed in Lighting
Instructions on page 27. Set wall thermostat to
desired temperature.
This thermostat has been electronically cali-
brated at the factory and requires no adjust-
ment or leveling.
Upon installation, the thermostat must be al-
lowed to stabilize at room temperature for a
minimum of 30 minutes for proper operation.
To turn the fireplace off, adjust thermostat to
the lowest setting and turn the gas control knob
back to PILOT. The pilot will remain lit.
IMPORTANT:
To turn the pilot off, turn the
gas control knob on the heater to the OFF
position.
OpERATING OpTIONAL
BLOWER ACCESSORY
Locate the blower controls by opening the lower
louver panel on the fireplace. Blower controls
are located on the left side of the switch bracket
to the left just inside the louver panel.
The BK manual blower and the BKT thermo-
statically-controlled blower have an ON setting
and an OFF setting. The blower will only run
when the switch is in the ON position. In the
OFF position, the blower will not operate.
Note for BKT Only:
If you are using BKT
blower with optional thermostat (wall mounted
or remote control) for the fireplace, your fire-
place and blower will not turn on and off at the
same time. The fireplace may run for several
minutes before the blower turns on. After the
heater modulates to the pilot position, the blow-
er will continue to run. The blower will shut off
after the firebox temperature decreases.
The blower helps distribute heated air from
the fireplace. Periodically check the louvers of
the firebox and remove any dust, dirt, or other
obstructions that will hinder the flow of air.
Figure 53 - Thermostat Hand-Held
Remote Control Unit HRC200
LOCK
MANU
AUTO
ºC/ºF
TEMP
POWER
ROOM
TEMP
SET
TEMP
AUTO
Turns
Hand-Held
Remote On
or Off and
Allows You
to Choose
the Manual
Setting
Selects
AUTO
Mode
°C/°F Mode
Button
Locks
System to
Prevent
Accidental
Ignition
Turns
Burners
On or
Off
Increases or
Decreases
Room
Temperature
in AUTO
Mode
Digital Display Shows
Temperature and Settings