Bonaire H2 Optimiser User Manual
Page 4

I
NSTALLATION
/
M
AINTENANCE
I
NSTRUCTIONS
H
2
Optimiser
Maintenance Requirements
1. Start Up Maintenance:-
With a new product there is the opportunity for new product residuals to
make their way into the water reservoir. After approximately 8 hours of
operation, check the following:-
•
Check and clean out any water blockage in the A/C6.
•
Check and clean out any water blockage in the water outlet
solenoid filter.
•
The unit tank / reservoir may need to be cleaned out. Remove the
over flow pipe and wash the tank out.
2. Annual Maintenance:-
Annual inspection of the water outlet and the CARE-FREE Water
Conditioner A/C 6 is recommended.
•
To clean the sacrificial anode, remove and soak it in vinegar for 5 –
10 minutes. Rinse off with water before reinstalling it.
•
If the anode is oxidized scrape clean. Replace the anode if
severely corroded.
The longevity of the anode is determined by the type of water it is
immersed in.
•
Check and clean out any water blockage in the A/C6.
•
Check and clean out any water blockage in the water outlet
solenoid filter.
•
Clean the unit tank / resevoir