Control installation & setup, Installing the control, Before starting – Bonaire Deluxe Control (LV) - PNE User Manual
Page 9: Installation, Nstalling, Ontrol
Manual Comfort Control
Control Installation & Setup
PNE2002 Series Control
Page 9
Control Installation & Setup
Installing The Control
Before Starting
Before attempting to locate the control, check that the 20 metre cable supplied will reach between the
air conditioner and the proposed wall control position.
For the unit to function a jumper supplied with the wall control must be fitted to the air conditioner control
box.
NOTE: Do not run the low voltage loom in long parallel runs with 240V mains cables. Keep the
low voltage loom 200mm away from any long runs of mains wiring.
Cross over mains wiring at right angles.
Do not use existing access holes in wall cavities where 240V mains wiring exists. Drill
a new access hole 200mm from the existing hole.
Installation
As the MANUAL control has no thermostat, the control can be installed anywhere that is suitable to the
customer and installer.
• Fit the communication cable through the dropper duct when installing the unit on the roof.
• Connect cable to one of the communication ports in the control box.
• Drill an access hole through wall
where the control will be
positioned.
• Pull the low voltage cable down
the wall and through the access
hole.
• Fit the MANUAL wall control base
plate to the wall.
• Connect the communication cable
to either port in the control box.
• Connect the communication cable
to the port in the wall control.
• Fit the wall control to the base.
• Fit the black jumper provided to
pins 1 & 2 in the air conditioner
control box. See wiring diagram .
• Connect the 240V power to the
unit.
• Turn the unit isolating switch on.
The unit is now ready for operation.
NOTE: Check the jumper has been fitted to pins 1 & 2 on the unit control board. If a service call
results in a jumper not being fitted, the customer will receive a charge for the service call out.