Command and parameter list – Denon AVR-3808 User Manual
Page 9
- 9 -
COMMAND and PARAMETER list
COMMAND PARAMETER
function example
PW
ON
POWER ON/STANDBY change
PWON
STANDBY
PWSTANDBY
?
Return
PW
Status
PW?
MV
UP
MASTER VOLUME UP/DOWN , direct change to **dB
MVUP
DOWN
MVDOWN
**
**:00 to 99 by ASCII , 80=0dB, 99=---(MIN)
MV80
?
Return
MV
Status
MV?
CV
FL UP
CHANNEL VOLUME UP/DOWN , direct change to **dB
CVFL UP
FL DOWN
---FRONT Lch
CVFL DOWN
FL **
**:38 to 62 by ASCII , 50=0dB
CVFL 50
FR UP
CVFR UP
FR DOWN
---FRONT Rch
CVFR DOWN
FR **
**:38 to 62 by ASCII , 50=0dB
CVFR 50
C UP
CVC UP
C DOWN
---CENTERch
CVC DOWN
C **
**:38 to 62 by ASCII , 50=0dB
CVC 50
SW UP
CVSW UP
SW DOWN
---SUBWOOFERch
CVSW DOWN
SW **
**:00,38 to 62 by ASCII , 50=0dB,00=OFF
CVSW 50
SL UP
CVSL UP
SL DOWN
---SURROUND Lch
CVSL DOWN
SL **
**:38 to 62 by ASCII , 50=0dB
CVSL 50
SR UP
CVSR UP
SR DOWN
---SURROUND Rch
CVSR DOWN
SR **
**:38 to 62 by ASCII , 50=0dB
CVSR 50
SBL UP
---SURROUND BACK Lch (SBch 2SP)
CVSBL UP
SBL DOWN
CVSBL DOWN
SBL **
**:38 to 62 by ASCII , 50=0dB
CVSBL 50
SBR UP
---SURROUND BACK Rch (SBch 2SP)
CVSBR UP
SBR DOWN
CVSBR DOWN
SBR **
**:38 to 62 by ASCII , 50=0dB
CVSBR 50
MV, CV COMMAND : "*" parameter uses two or three ASCII characters. (see page4 J) section)