Ducted Evaporative Air Conditioning
MOTOR
AND
FAN
Check that the fan spins freely and that there is no build up on the blades.
ELECTRICAL
No general maintenance is required to the electrical system.
A Qualified Electrician should only carry out electrical connections and maintenance.
BLEED
OFF
The bleed rate should be checked to ensure it is adequate and that there is no build up of mineral deposits
in or on your air conditioner. White deposits indicate high mineral content and the Bleed Rate should be
increased. If it is at maximum and the deposits are still forming, then more regular maintenance is required.
PUMP
Check the pump spins freely and that the strainer is clean.
WATER
DISTRIBUSTION
Check the water distribution system for blockage. Check the delivery tube for kinks or holes. Check that the
clamps are secure and in place.
NO
SEASONAL
MAINTENANCE
Your unit has been supplied with an Aquamiser. As long as the Aquamiser has been fitted, there is no need
for regular checking of the system during the operating (summer) period. This however does not remove the
responsibility of the customer to have the unit serviced on an annual basis to check the unit function and to
ensure the unit is clean and free from any mineral deposit build up.