Advanced Control Technologies RP124 (A10 120VAC, 15A, PLUG-IN,RELAY RECEIVER) User Manual
Page 2

0615-01
2
ADVANCED CONTROL TECHNOLOGIES, INC.
Indianapolis, Indiana 46278
RP124 Installation Instructions
P/D 092702
WITHOUT A LOAD CONNECTED:
Note: If you first plug the RP124 into an outlet it will respond only to commands addressed at A1.
1. To change the address, hold in the push-button on the front of the module, insert the RP124
into the receptacle, or apply power if connected to a controlled circuit. Two to three clicks will
be heard to indicate it is the configure mode. Release the push-button.
NOTE: The module waits for a new address to be configured for up to 1 minute. If a new address is
not received within that time, the module will turn off and continue to respond to the old address.
2. Now transmit the desired address twice with a 1 second pause between transmissions (can be
any single address from A1 to P16) or address plus command (can be ON or OFF). Irrespective
of the configuration command, the RP124 will turn OFF indicating the new address is now
configured.
3. The module will now respond to the new address. Now send an ON command. If the module turns
ON (an audible click will be heard) it is configured correctly.
OPERATION
With any controller that supports X10 commands, the RP124 can be remotely turned on and off, or
respond to the ALL UNITS OFF command.
To manually turn the module on and off, tap the push-button on front of the unit quickly.
If unplugged or if power is lost, when plugged back in, the output will revert to the state before power
was lost.
CHECKOUT
1. Test Operation:
Using a test or desktop transmitter, transmit the programmed address to ensure the module
controls the load in response to remote control.
2. Test for Signal Strength and Noise once again using appropriate PCC test equipment.
Supply Voltage
120 VAC, +/-10%, 50 or 60 Hz
Power Consumption
Less than 4.5W
Signal Input
120 KHz +/- 4 KHz, sensitive to 50 millivolts
peak to peak
Maximum switching capacity
15 Amps or 1800 VA
Maximum switching voltage
120 VAC