18 power jumper settings, Jp1: at/atx mode, Cn2: pwr_ok config – ADLINK Express-BASE6 User Manual
Page 30: Jp2: ps_on# signal source, Jp3: at power 5v setting, Jp3: 5vsb to module source
Express-BASE6 User’s Manual
Page 30
JP1:
AT/ATX MODE
In AT mode, JPY1 shorts PS_ON# to ground
directly to force power on. See 8.6 AT Power
Mode on p. 38.
Jumper
Status
1-2
ATX Mode
<<<<
2-3
AT Mode
1
2
3
CN2:
PWR_OK Config
Jumper
Status
1-2
Add 3.3V Pullup with 10K to signal PWR_OK
3-4
Connect PWRGOOD of ATX power supply
<<<<
5-6
Connect PWRGOOD of onboard DCDC regulator
Note:
<<<< indicates default setting
6.18 Power Jumper Settings
JP2:
PS_ON# Signal Source
Jumper
Status
1-2
SUS_S3#
<<<<
2-3
SUS_S5#
1
2
3
All ADLINK modules support S3 mode and
consecutive power down of ATX power supply.
For modules that connect the S3 signal, PS_ON#
should always be set to SUS_S3# as source (even when S3 mode is disabled in the BIOS). For
modules that do not bring out the S3 signal, PS_ON# should be set to SUS_S5# as source.
JP3:
AT Power 5V Setting
With an AT power supply is connected to
the Express-BASE6, JP3 can be used to
provide 5VSB to the COM module from
the carrier board.
Jumper
Status
1-2
AT without P5V
<<<<
2-3
AT with P5V
1
2
3
JP3: 5VSB to Module Source
Jumper
Status
1-2
5VSB produced on
carrier from Vcc
2-3
5VSB from ATX power
supply
3-4
No 5VSB from module