Input characteristics, Output characteristics – ADLINK cPCIS-ET2600 Series User Manual
Page 42
36
•
Power Supply Unit
Input Characteristics
•
Input Voltage: Typ. 90-264VAC
• Power
Factor
Correction: Meets Harmonic Correction
EN 61000-3-2.
•
Input Connector: CompactPCI 47-pin power connector
•
Input Frequency: 47-63Hz
•
Inrush Current: Less than 15A@240VAC
•
Input Current: 3.6A@230VAC/ 4A@260VAC
•
EMI: Meets EN55022 / FCC Class A
•
Hold-up Time: 20mS after power fail signal
•
Remote ON/OFF: Available at [INH#] & [EN#] pins
•
Power Fail Signal: Available at [FAL#] pin
•
Status LED:
critical fault.
•
Thermal Protection (OTP): Installed NTC and thermostat for thermal
sensor at [DEG#] pin
•
Power OK: Installed at all outputs
•
Leakage Current: 1.18mA at 254VAC/60Hz
Output Characteristics
Output Current (A)
Output
Voltage
Min.
Max.
Typ.
Peak
5V
0 40.0
25.0 –
3.3V
0 40 20 –
12V
0 5.5 4 –
-12V
0 2 1 –
•
Over Load Protection: Fully protected against output overload or
short circuit. Typical 120% max. load.
•
Over Current Protection: Installed at each rail
•
Output Wattage: Typ. 250W continuous.
•
Output Connector: CompactPCI 47-pin power connector.
•
Line Regulation: Max. ±10mV
•
Load Regulation: 3.3V & 5V: ± 10mV, +12V: ± 30mV & -12V: -380
mV.