beautypg.com

Input characteristics, Output characteristics – ADLINK cPCIS-ET2600 Series User Manual

Page 42

background image

36

Power Supply Unit

Input Characteristics

Input Voltage: Typ. 90-264VAC

• Power

Factor

Correction: Meets Harmonic Correction

EN 61000-3-2.

Input Connector: CompactPCI 47-pin power connector

Input Frequency: 47-63Hz

Inrush Current: Less than 15A@240VAC

Input Current: 3.6A@230VAC/ 4A@260VAC

EMI: Meets EN55022 / FCC Class A

Hold-up Time: 20mS after power fail signal

Remote ON/OFF: Available at [INH#] & [EN#] pins

Power Fail Signal: Available at [FAL#] pin

Status LED: means valid input voltage; means a
critical fault.

Thermal Protection (OTP): Installed NTC and thermostat for thermal
sensor at [DEG#] pin

Power OK: Installed at all outputs

Leakage Current: 1.18mA at 254VAC/60Hz

Output Characteristics

Output Current (A)

Output

Voltage

Min.

Max.

Typ.

Peak

5V

0 40.0

25.0 –

3.3V

0 40 20 –

12V

0 5.5 4 –

-12V

0 2 1 –

Over Load Protection: Fully protected against output overload or
short circuit. Typical 120% max. load.

Over Current Protection: Installed at each rail

Output Wattage: Typ. 250W continuous.

Output Connector: CompactPCI 47-pin power connector.

Line Regulation: Max. ±10mV

Load Regulation: 3.3V & 5V: ± 10mV, +12V: ± 30mV & -12V: -380
mV.