NuDAM-6521

61

@Description
Read module‘s name.

@Syntax
$(Addr)M

$

Command leading code.

(Addr) Address

ID

M

Read module name

@Response
!(Addr)(ModuleName)

or

?(Addr)

!

Command is valid.

?

Command is invalid.

(Addr) Address

ID.

(ModuleName)

NuDAM module‘s name.

@Example

User command:

$30M

Response:

!306521

!

Command is valid.

30 Address
6521

ND-6521 (RS-422/485 to RS-232 converter)