Destination trigger routing, Halfway, Err_noerror err_boardnoinit err_set_path – ADLINK PXI-3950 User Manual
Page 74
60
Appendix
A
dest
Destination Trigger Routing.
halfway
Halfway Point Trigger Routing. This parameter is used only
when users want to route the software-generated trigger signal
to the SMB connector on the faceplate. In this case, users
should set the halfway as one of the trigger bus lines. Other-
wise set the halfway as PXI_TRIG_VAL_NONE.
@ Return Codes
ERR_NoError
ERR_BoardNoInit
ERR_Set_Path
Available value
Description
PXI_TRIG_VAL_SMB
SMB connector on the faceplate
PXI_TRIG_VAL_TRIG0
PXI trigger bus #0
PXI_TRIG_VAL_TRIG1
PXI trigger bus #1
PXI_TRIG_VAL_TRIG2
PXI trigger bus #2
PXI_TRIG_VAL_TRIG3
PXI trigger bus #3
PXI_TRIG_VAL_TRIG4
PXI trigger bus #4
PXI_TRIG_VAL_TRIG5
PXI trigger bus #5
PXI_TRIG_VAL_TRIG6
PXI trigger bus #6
PXI_TRIG_VAL_TRIG7
PXI trigger bus #7
Available value
Description
PXI_TRIG_VAL_NONE
No halfway point
PXI_TRIG_VAL_TRIG0
PXI trigger bus #0
PXI_TRIG_VAL_TRIG1
PXI trigger bus #1
PXI_TRIG_VAL_TRIG2
PXI trigger bus #2
PXI_TRIG_VAL_TRIG3
PXI trigger bus #3
PXI_TRIG_VAL_TRIG4
PXI trigger bus #4
PXI_TRIG_VAL_TRIG5
PXI trigger bus #5
PXI_TRIG_VAL_TRIG6
PXI trigger bus #6
PXI_TRIG_VAL_TRIG7
PXI trigger bus #7