Acrosser AR-V5403FL User Manual
Page 33
Revision: 1.0
33
C. Hard off delay: 5 minutes
Mode 4:
A. Same as mode 2 except for soft/hard off delay time
B. Soft off delay: 30 minute
C. Hard off delay: 2 Hours
Mode 5: See Figure 2
Same as mode 2 except that the power on is controlled by remote switch.
A. Power on is controlled by remote switch (ignition must be turned on 2 seconds
before remote switch is pressed).
B. AR-PW0932V sends off pulse to motherboard 5 seconds after ignition is turned off or
remote switch is pressed. (Soft delay)
C. Hard off delay: 1 minutes
Mode 6:
A. Same as mode 5 except for soft/hard off and delay
B. Soft off delay: 1 minute
C. Hard off delay: 5 minutes
Mode 7:
A. Same as mode 5 except for soft/hard off and delay
B. Soft off delay: 30 minute
C. Hard off delay: 2 Hours
Mode15(Software control mode):
A. Setting by
AP
B. Software mode default as Hardware mode 2
C. Soft off delay time can be set
D. Hard off delay time can be set
E. In-Vehicle system power on by ignition or Remote button can be set
F. Show Ignition status / Voltage(for AP only)
G. Create a button "Set default"
Plan AP screen
Æ
Engine status Car Battery
System on by Ignition Remote Switch
Soft off delay time seconds
Set Default
OK
Cancel