Smart Mode (Mode 2 to Mode 7)

Mode 2: See Figure 1

A. Power on is controlled by ignition (remote switch does not make any action to

power on).

B. Power on retry: If the motherboard cannot be turned on normally (/PSON does not go

to low), the Power smart function will turn off 5VSB, and then turn on 5VSB and retry.

Send “on” pulse to motherboard again. The power board will re-try this procedure

until successfully turn on motherboard.

C. Power smart function sends “ON” pulse to motherboard when ignition is on for

more than 2 seconds.

D. Power smart function will ignore the status change of ignition after ON pulse is

send to motherboard for 3 minutes. After this period, the Power smart function will

start to check its status. This can avoid an improper “OFF” process before the OS is

complete booted.

E. Power off is controlled by remote switch or ignition. Remote switch has higher

priority than ignition. (Remote switch is optional).

F. Power smart function sends “off” pulse to motherboard 5 seconds after ignition is

turned off or remote switch is pressed. (Soft delay)

G. Power smart function will ignore the status change of ignition and remote switch

during the “OFF” pulse is sent out and the /PSON return to high. This will avoid an

improper ON process before the motherboard is completely shot off.

H.

The

digital output (optional) will go from high to low at the moment that “OFF”

pulse is sent to motherboard. The low state will be kept until /PSON back to high. If

the /PSON does not back to high within 3 minutes, the Power smart function will enter

a retry cycle (described in next section).

I. Power off retry: If the motherboard cannot be shouted down normally (/PSON does

not go to high) within 3 minutes after “OFF” pulse is sent, the Power smart function

will send off pulse to motherboard again. If the motherboard still cannot be shouted

down normally, the power output will be turned off directly. (Figure 3)

J. Hard off delay: 1 minutes, During this period system can be turned on again if the off

procedure already finished and power button is pushed again(or ignition on again)

Mode 3:

A. Same as mode 2 except for soft/hard off delay time

B. Soft off delay: 1 minute