Directed Electronics PYTHON 480XP User Manual
Page 22
22
©
2002
Directed Electronics, Inc.
5.
Release. The Valet®/Program switch can now be released.
For example, to program the arming mode from active to passive, within 10 seconds of turning the
ignition off, select Menu One and press and release the Valet/Program switch once. Then press it
again and hold it. The LED will flash in groups of one and the horn will honk once (if connected).
While holding the Valet®/Program switch, press the unlock button. The LED will stop flashing and
go out. The horn will honk twice if connected. Passive arming is now programmed. If that was not
the desired setting, without releasing the Valet®/Program switch, press the lock button. The LED
will light solid and the horn will honk once if connected. Active arming is now programmed.
Release the Valet®/Program switch after the selection has been made.
You can advance from feature to feature by pressing and releasing the Valet®/Program switch the
number of times necessary to get from the feature you just programmed to the feature you wish to
access. For example, in Menu One, if you just programmed Feature 1-2 and you next want to
program Feature 1-3 to off, release the Valet/Program switch. Press and release it once to advance
from Feature 1-2 to Feature 1-3. Then press it once more and hold it. The LED will flash in groups
of 3 and the horn will honk 3 times (if connected) to confirm that you have accessed Feature 1-3.
The learn routine will be exited if:
➤
The ignition is turned on.
➤
The Valet/Program switch is pressed too many times.
➤
More than 15 seconds elapses between programming steps.
One long horn honk (if connected) indicates that the Learn Routine has been exited.