beautypg.com

Installation – Desa RH10PT User Manual

Page 8

background image

www.desatech.com

110373-01E

8

INSTALLATION

Continued

CONNECTING TO PORTABLE
CYLINDER GAS SUPPLY

WARNING: Review and un-

derstand the warnings in the

Safety Information section, page

3. They are needed to safely op-

erate this heater. Follow all local

codes when using this heater.

WARNING: Test all gas piping

and connections for leaks after

installation or servicing. Never

use an open flame to check for

a leak. Apply a noncorrosive

leak detection fluid to all joints.

Bubbles forming show a leak.

Correct all leaks at once.

WARNING: Use pipe joint

sealant that is resistant to liquid

petroleum (LP) gas.

Never bring a refillable pro-

pane/LP cylinder indoors. A fire

or explosion can occur causing

property damage, serious injury

or death.

IMPORTANT:

You must use a propane/LP gas

supply cylinder that is compatible with the connec-

tion device provided with the hose and regulator.

1. Remove 90° gas fitting from hardware bag.

2. Apply pipe joint sealant lightly to male NPT

threads (see Figure 10). This will prevent excess

sealant from going into pipe. Excess sealant in

pipe could result in clogged heater valves.

3. Hold gas pressure regulator with wrench when

connecting the 90° gas fitting. Do not over

tighten connection to regulator. The regulator

body could be damaged.

4. Provide propane/LP supply system (see Pro-

pane/LP Supply, page 5).

5. Connect fuel gas fitting on hose/regulator assem-

bly to propane/LP tank(s). Turn fuel gas fitting

counterclockwise into threads on tank. Tighten

firmly using a wrench. IMPORTANT: Position

regulator so that hose leaving the regulator is

in a horizontal position (see Figure 11). This

places the regulator vent in the proper position

to protect it from the weather.

6. Connect hose to heater inlet. Tighten firmly

using a wrench. You must use the regulator

supplied with heater.

7. Open propane/LP supply valve on propane/LP

tank(s) slowly. Note: If not opened slowly,

excess-flow check valve on propane/LP tank

may stop gas flow. If this happens, close pro-

pane/LP supply valve and open again slowly.

8. Check all connections for leaks. Apply a noncor-

rosive leak detection fluid to gas joints. Bubbles

forming show a leak that must be corrected.

9. Close propane/LP supply valve.

Propane/LP
Tank

Propane/LP
Supply Valve

Regulator

Hose To
Heater

Fuel Gas
Fitting

Figure 11 - Regulator Position

Figure 10 - Gas Connection

Heater
Cabinet

Pressure
Regulator

Elbow

Hose To
Regulator

Hose Fitting

Apply Sealant To
This End Only

CONNECTING TO PERMANENT
GAS SUPPLY

WARNING: This appliance

requires a 3/8" NPT (National

Pipe Thread) inlet connection to

the pressure regulator.

WARNING: A qualified ser-

vice person must connect heater

to gas supply. Follow all local

codes.