beautypg.com

Planning guide – Dacor RGC365 User Manual

Page 2

background image

PLANNING

GUIDE

Web: http://www.Dacor.com

Corporate Phone: 800-793-0093

Specifications are subject to change without notice.

See installation instructions for additional details.

4.12

RGC304, RGC365

30”, 36” Wide, Preference™

Renaissance Gas Cooktops

2/2

Revised

05/21/08

13" Max.

(330 mm)

A

3 1/8" Min.

(79 mm)

18" Min.

(457 mm)

30" Min.

(762 mm)

Clearances to Combustibles

1/4” (6 mm)

Mimimum clearance

to combustible

surfaces

B

Under Cabinet Clearances

Model

A: Minimum

A: Recommended

RGC304

30” (762 mm)

36” (914 mm)

RGC365

36” (914 mm)

42” (1067 mm)

Model

B: Minimum

RGC304

29” (737 mm)

RGC365

35 ¼” (895 mm)

All tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted.

RGC304

RGC365

RGC304LP

RGC365LP

Total Connected

Load

0.25 Amps

(0.03 kW)

0.25 Amps

(0.03 kW)

Circuit

Requirement

120 Vac,

60 Hz, 15 Amp

120 Vac,

60 Hz, 15 Amp

Gas Type

Natural

LPG

Manifold

Pressure

5” Water Column

10” Water Column

Min. Gas Supply

Pressure

6” Water Column

11” Water Column

Power Cord

Length

40” (1016 mm)

10” (254 mm)

GAs AND ELECtRICAL REqUIREmENts*

* The data above is for reference only. If the above data does not

agree with the product data label, use the data on the product data

label.

Front of Unit

Data Label

This manual is related to the following products: