beautypg.com

Care and maintenance, Maintenance, Warning – Dacor EPICURE EHR42 User Manual

Page 8: 23 1 b a

background image

6

Care and Maintenance

Maintenance

Light bulb Replacement

WARNING

To prevent electric shock turn off power at the fuse or

junction box before replacing the light bulb.
To avoid personal injury, make sure the cooktop

or range, the hood and the light are cool before

changing the light bulb.

Light bulb replacement is considered to be a hom-

eowner maintenance operation. If all of the lights do

not work, before replacing any bulbs, check to make

sure power is on at the circuit breaker or fuse box.
Replace the light bulbs only with Dacor Part No.

700975. Halogen Bulb Replacement Kit consist of

a single bulb and suction cup, available from any

authorized Dacor parts dealer.

To replace the light bulb:

Remove the right filter and turn off the main power

1.

switch.
Gently push the suction cup on the light replace-

2.

ment tool

A

(provided with you range hood)

onto the lens of the light bulb

B

.

Turn the tool counter-clockwise until the bulb

3.

comes loose.
Remove the tool from the bulb and put it on the

4.

lens of the replacement bulb.

Screw the new bulb into the light fixture clockwise

5.

until it is tight. Turn on power at the fuse or junc-

tion box. Turn on the main power switch and touch

the light key to make sure it is working.
Replace the filter.

6.

Replacement Parts

Dacor Part

Number

Description

700975

Halogen bulb replacement kit

101617

Filter

Product Specifications*

Total Connected

Load

120 Vac, 60 Hz, 9 Amp. Max.

(10 Amp. max surge)

Filters

Mesh type, dishwasher safe

Lights

120 Vac, 60 Hz., 75 Watt

* Specifications subject to change without notice

2

3

1

b

A