Trouble shooting guide – Dimplex EWMC-CC-SS User Manual
Page 3

EWMC-CC-SS
TROUBLE SHOOTING GUIDE
 
 
 
 
HEATER
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Problem
Cause
Solution
Service Manual 
Reference 
Defective manual selection 
switch 
Replace manual selection 
switch 
Page 8
Defective circuit board
Replace circuit board
Page 14
Improper operation
See User’s Guide
 
Heater is not 
turning off 
 
 
Loose wiring
Trace wiring in unit
Page 5
Defective manual selection 
switch 
Replace manual selection 
switch 
Page 8
Defective circuit board
Replace circuit board
Page 14
Defective heater assembly
Replace heater assembly
Page 12
Improper operation
See User’s Guide
 
Heater is not 
turning on 
 
 
 
Loose wiring
Trace wiring in unit
Page 5
Normal operation
Normal operation is when 
the heater emits an odour for 
a brief period after the 
heater is initially turned on. 
The heater is burning off any 
dust accumulated during 
manufacturing or operation. 
Defective heater assembly
Replace heater assembly
Page 12
 
Heater emits an 
odour 
Loose wiring
Trace wiring in unit
Page 7 - 9
Improper operation
See User’s Guide
Defective thermostat
Replace thermostat
Page 9
Loose wiring
Trace wiring in unit
Page 5
Heater fan turns on 
but heater lacks 
heat 
Defective heater assembly
Replace heater assembly
Page 12
Normal operation
Small glowing sections of 
the element are considered 
normal. 
Heating element is 
glowing red 
Defective heater assembly
If larger glowing sections are 
causing the heater to trip the 
thermal cut out, unplug unit, 
discontinue use and replace 
heater assembly 
Page 12