beautypg.com

Trouble shooting guide – Dimplex EWMC-CC-SS User Manual

Page 2

background image

EWMC-CC-SS

TROUBLE SHOOTING GUIDE




GENERAL

Problem

Cause

Solution

Service Manual
Reference

Circuit breaker trips
or fuse blows when
unit is turned on

Improper circuit current rating

Additional appliances may
exceed the current rating of
the circuit breaker or fuse.
Plug unit into another outlet
or install unit on a dedicated
15 amp circuit

Optional remote control has a
similar frequency to other
remotes in the area
Radio frequency disturbance
from outside sources



Replace hand held remote
control


Unit turns on or off
by itself

Defective circuit board

Replace circuit board

Page 14

Lights dim in room
while the unit is on

Unit is drawing close to circuit
current rating

Move the unit to another
outlet or install unit on a
dedicated 15 amp circuit

Normal operation

The power cord may get
slightly warm to the touch
when the heater is on

Power cord gets
warm

Defective power cord

Replace power cord

Page 16


APPEARANCE























Problem

Cause

Solution

Service Manual
Reference

Improper operation

Refer to User’s Guide

Defective main on/off switch

Replace main on/off switch

Page 7

Defective remote control

Install new battery into the
handheld transmitter and
reconfigure remote

Page 2

Defective circuit board

Replace circuit board

Page 14


Fireplace does not
turn on

Loose wiring

Check wiring connections

Page 5

Defective flame motor

Replace flame motor

Page 10


Flame frozen

Loose wiring

Check wiring connections

Page 5

Burnt light bulbs

Replace light bulbs

Page 6

Loose wiring

Check wiring connections

Page 5


Flame not bright or
flame not visible

Defective light harness

Replace light harness

Log set dim, ember
bed not glowing

Burnt light bulbs

Replace light bulbs

Page 6

Flame Shutter

Defective flame motor

Replace flame motor

Page 10