Datalogic Scanning Jet User Manual
Page 54

DATALOGIC JET™
3
Default Settings
The following tables contain the default values for the major barcode setup
parameters, according to the type of scan engine mounted on the PDA. For a
complete list of parameters and of their configuration procedures, please refer to the
SDK Help file on the CD.
SCAN PARAMETERS
HP Laser
Imager
RFID+Laser
ScanTimeout 5000
Not
available 5000
GoodReadSound Beep.wav
Beep.wav
Beep.wav
LedDuration
200 ms
200 ms
200 ms
LedPulses 1
1
1
ContinuousMode Disabled
Disabled
Disabled
KeyboardEmulation Disabled
Disabled
Disabled
SoftTrigger Enabled
Enabled
Enabled
ScanAlwaysOn Disabled
Disabled
Disabled
NotPrintableChar Leave
Leave
Leave
BARCODE SYMBOLOGY
SPECIFIC
READER PARAMETERS
HP Laser
Imager
RFID+Laser
UPC A
Enabled Enabled
UPC E
Enabled Enabled
EAN 8
Enabled Enabled
EAN 13
Enabled
*
Enabled
UPC E1
Disabled
EAN Bookland
Disabled
UPC/EAN/JAN
Enabled
Code 39
Enabled Enabled Enabled
Code 39 Full ASCII
Disabled Disabled Disabled
Code 32
Disabled
Disabled
Code 39 Trioptic
Disabled
2/5: Interleaved
Enabled Enabled Enabled
2/5: Industrial
Disabled
Disabled
2/5: Matrix
Disabled
Code 128
Enabled Enabled Enabled
EAN 128
Enabled Disabled
Enabled
ISBT 128
Disabled
Codabar
Enabled Enabled Disabled
RSS
Disabled
* In the Imager models these codes may only be enabled or disabled as a group by the
UPC/EAN/JAN family selection (see a few lines below).
38