Part 1 - INSTALLATION INSTRUCTIONS

1 - GENERAL INFORMATION

This cooker hood is designed to be installed in the lower part of a cabinet placed above a hotplate
fitted against a wall. It can be used either in the extraction (ducted to the outside) or in the recirculation
mode (internal recycling).

Before starting the installation, consideration should be given to the difticulties to be found
during installation.
The installation work must be undertaken by a qualified and competent person in conformity

to the rules concerning the evacuation of contaminated air.
The manufacturer disclaims all liability for any damage or injury caused as a result of not

following the instructions for installation contained in the following text.

2 - SAFETY WARNINGS

2.1 • When used in the extraction mode, the cooker hood ducting must not be connected to a flue

which is used for exhausting fumes from appliances supplied with energy other than electric,
such as a central heating flue or water heating flue.

2.2 - Before connecting to the mains supply ensure that the mains voltage corresponds with the

voltage on the rating plate inside the hood.

2.3 - Connect the cooker hood to the mains via a bipolar switch which has 3 mm clearance between

the contacts.

2.4 - The appliance must be earthed.
2.5 - When installed, the hood must be positioned at least 65 cm above the hotplate.
2.6 - Never do flambé cooking under this cooker hood.
2.7 - Never leave frying pans unattended during use as overheated fat and oil may catch fire.
2.8 - Before carrying out any kind of maintenance or cleaning, disconnect the hood from the mains

supply.

2.9 • If the room where the cooker hood is to be used contains a fuel burning appliance such as a

central heating boiler then this must be of the room sealed or balanced flue type. If other types
of flue or appliance are fitted, ensure that there is an adequate supply of air into the room.
When the cooker hood is used in conjunction with appliances supplied with energy other than
electric, the negative pressure in the room must not exceed 0,04 mbar to prevent fumes being
drawn back into the room by the cooker hood.

3 - INSTALLATION

This unit belongs to the category of semi-fitted hoods. The top portion is inserted inside the overhead
unit. After assembly, the pull-out undercarriage is positioned outside the overhead unit and must be
pulled out into a working position.

3.1 - Installation in the overhead unit

Using the template provided, cut the opening required to insert the top portion of the hood in the base
of the overhead unit. Open the pull-out undercarriage and remove the blower grid, position the hood
in the opening and fix the bottom portion using the screws in the bag of fittings provided.

3.2 - Fitting the spacer

After having fixed the hood to the overhead unit, the spacer provided can be fitted to the bottom, to

close the space remaining between the rear edge of the hood and the wall.
The spacer can be adjusted from a minimum of 1 mm to a maximum of 30 mm.

3.3 - Connecting up remote blower or filter system

1 - Connecting up remote blower system

The hood must be connected to the external air outlet using 0 120 mm rigid or flexible pipes, fixed
using suitable hose clamps (not provided).