Model 3vg79, Assembly, Ventilation – Dayton 3VG79 User Manual

Page 5: Operation

background image

Dayton Operating Instructions and Parts Manual

5

Model 3VG79

Version B - For Reduction

G016.J

®

Front
Handle

Rear
Handle

Wheel
Support
Frame

Hot Air
Outlet

Fuel
Tank
Flange

Screw

Air
Inlet

Assembly

This model is furnished with wheels and
handles. Wheels, handles, and the
mounting hardware are found in the
shipping carton.

TOOLS NEEDED

• Medium Phillips Screwdriver
• 3/8" Open or Adjustable Wrench
• Hammer

1. Slide axle through wheel support frame.

Install wheels on axle.

IMPORTANT: When installing wheels,
point extended hub of wheels toward
wheel support frame (See Figure 4).

2. Place cap nuts on axle ends. Gently tap

with hammer to secure.

3. Place heater on wheel support frame.

Make sure air inlet end (rear) of heater
is over wheels. Line up holes on fuel
tank flange with holes on wheel support
frame.

4. Place handles on top of fuel tank flange.

Insert screws through handles, fuel tank
flange, and wheel support frame.
Attach nut finger tight after each screw
is inserted.

5. After all screws are inserted, tighten

nuts firmly.

Wheel

Extended
Hub

Nut

Cap Nut

Axle

Figure 4 - Wheel and Handle Assembly

Follow the mini-
mum fresh, outside

air ventilation requirements. If proper
fresh, outside air ventilation is not
provided, carbon monoxide poisoning
can occur. Provide proper fresh, outside
air ventilation before running heater.

FRESH AIR OPENING REQUIREMENTS

Square Feet

Heater Size

Opening

200,000 Btu/Hr

6.0

Ventilation

Review and
understand the

warnings in the Safety Information
Section. They are needed to safely
operate this heater. Follow all local
codes when using this heater.

TO START HEATER

1. Follow all ventilation and safety

information.

2. Fill fuel tank with kerosene or No. 1 fuel

oil.

3. Attach fuel cap.

4. Plug power cord of heater into three-

prong, grounded extension cord. Exten-
sion cord must be at least six feet long.

EXTENSION CORD WIRE SIZE
REQUIREMENTS

• 6 to 10 feet long, use 18 AWG

rated cord

• 11 to 100 feet long, use 16 AWG

rated cord

• 101 to 200 feet long, use 14 AWG

rated cord

5. Plug extension cord into standard 120

volt/60 hertz, three-hole, grounded outlet.
Heater will start when extension cord is
plugged into outlet. If not, push in flame-
out control reset button (See Figure 5).

Operation

Provide at least a three-square-foot
opening of fresh, outside air for each
100,000 Btu/Hr rating. Provide extra fresh
air if more heaters are being used.

Example: A 200,000 Btu/Hr heater
requires one of the following:

• a two-car garage door (16 feet wide

opening) raised five inches

• a single-car garage door (9 feet wide

opening) raised eight inches

• two windows (30 inches wide opening)

raised fifteen inches

Flame-out Control
Reset Button

Figure 5 - Flame-out Control Reset Button

TO STOP HEATER

1. Unplug extension cord from outlet.

TO RESTART HEATER

1. Wait two minutes after stopping heater.

2. Repeat steps under To Start Heater.