SPECIFICATIONS
Type:
Gain:
Input Sensitivity:
Power Output:
Frequency Response:
Input Impedance:
Load Impedance:
Load Voltage:
Output Impedance:
Noise Level:
Controls:
Power Supply:
Power Amplifier
61 dB
0.8 volt rms for rated output
50 watts at less than 1% THD,
50 to 12,000 Hz
±1 dB, 20 to 20,000 Hzatl
watt output.
±1 dB, 50 to 12,000 Hz at rated
output.
15.000 ohms (potentiometer)
600 ohms balanced with
15095A plug-in transformer
15.000 ohms balanced with
15335A transformer
4, 8, 16,100 ohms
14, 20, 28 (25V, 40-watt),
70 volts
Less than 10% of nominal
load impedance
—38 dBm or 85 dB below
rated output
Power on/off switch
Potentiometer, continuously
variable composition
High-pass filter switch (rear)
100/120/220/240Vac,
50/60 Hz
13 watts at zero signal
85 watts at 17 watts output
145 watts at 50 watts output
OR
ARCHITECT'S AND ENGINEER'S SPECIFICATIONS
The power amplifier shall be capable of operating
from a 100/120/220/240V ac line or from a
24/28V dc battery. The power supply shall auto
matically transfer the power to dc operation if ac
power fails. An octal socket shall be provided on
the rear panel for installation of an accessory line
transformer. The front panel shall be hinged to
permit access to the chassis interior without
removing the amplifier from the equipment rack.
The power amplifier shall meet the following per
formance criteria. Gain, 61 dB. Input sensitivity,
0.8V rms for rated output. Power output, 50 watts
at less than 1% THD from 50 Hz to 12 kHz. Fre
quency response at 1 watt output, ± t dB from 20
Hz to 20 kHz and ± 1 dB 50 Hz to 12 kHz at rated
Operating
Temperature Range:
Special Features:
Dimensions:
Weight:
Color:
Accessories (must be
ordered separately):
Design and
Performance
Approvals:
24/28 volts dc (battery (—) is
ground
0.2 amp at zero signal
2.5 amps at 17 watts output
4.0 amps at 50 watts output
Up to 50°C (131°F) ambient
Automatic transfer from ac
to dc power in the event of
ac power failure
Dissipation sensing device
for protection of output
transistors
High-pass filter (300 Hz)
5 1
/
4
" H X 19" Wx
7 3
/
8
" D
(13.33 cm Hx 48.26 c m W x
18.73 cm D)
23 pounds (10.45 kg)
Black
15095A Plug-in
Line Transformer
15335A Plug-in Bridging
Transformer
Underwriters Laboratories list
ing 209J for Commercial Audio
Systems, File E8783(N)
Underwriters Laboratories list
ing 89MO for Fire Protective
Signaling Systems, File
S2925(N)
output. Input impedance: 15,000 ohms (potenti
ometer), 600 ohms balanced with 15095A plug-in
transformer, 15,000 ohms balanced with 15335A
transformer. Load impedance; 4, 8, 16 and 100
ohms. Load voltage; 14, 20, 28 (25V, 40-watt),
and 70 volts. Output impedance, less than 10% of
nominal load impedance. Noise level, -38 dBm
or 85 dB below rated output. Operating tempera
ture range up to 55°C (13T*F) ambient. Dimen
sions, 5
’/4"
H x 19” W X
7 3 /8 ” D. Weight, 23
pounds. Color, black.
The power amplifier shall be Underwriters Labo
ratories listed for use in commercial audio systems
and fire protection signaling systems.