beautypg.com

Hardware installation (cont.) – DSC POWERSERIES PC1616 User Manual

Page 4

background image

Hardware Installation (Cont.)

4. AUX Power Wiring

The control panel can provide a maximum of 700mA of current for modules, powered detectors, relays, LED’s etc.… If the total current
required exceeds 700mA an additional power supply is required (e.g.,PC5200, PC5204). See list below.

NOTE: Min/max operating voltages for devices, sensors and modules is 9.5V

DC

- 14V

DC

Refer to the list of Compatible Devices on the first page for the current draw of individual devices

5. PGM Wiring

PGMs switch to ground when activated by control panel.
Connect the positive side of the device to be activated to the AUX+
Terminal. Connect the negative terminal to the PGM.
current output is as follows

PGM 1, 3, 4 .................... 50mA

PGM 2 .......................... 300mA

For currents levels greater than 300mA a relay is required.
PGM2 can also be used for 2-wire smoke detectors.

NOTE: Use SEOL resistors on Fire Zones ONLY.

PGM 1, LED Output with current limiting resistor and Optional Relay

driver output

2-wire Smoke Detectors Initiating Circuit

Style B (Class B), Supervised, Power Limited

Compatibility Identifier ........................................................ PC18-1

DC Output Voltage..................................................... 9.8-13.8 VDC

Detector Load ............................................................. 2 mA (MAX)

Single-end-of-line (SEOL) Resistor ..................................... 2200

Loop Resistance............................................................24

Ω (MAX)

Standby Impedance.................................................. 1020

Ω (ΝΟΜ)

Alarm Impedance ........................................................570

Ω (MAX)

Alarm Current ............................................................ 89 mA (MAX)

Compatibility ID For FSA-210B Series is: FS200

4-wire Smoke Detectors

6. Telephone Line Wiring

Wire the telephone connection terminals (TIP, Ring, T-1, R-1) to an
RJ-31x Connector as indicated.

For connection of multiple devices to the telephone line, wire in the
sequence indicated.
Telephone format is programmed in section [350].
Telephone Call Directions are programmed in section [351]-[376].

7. Ground

8. Battery

9. AC Wiring

Ground Installation

A sealed, rechargeable, lead
acid battery or gel type battery is
required to meet UL require-
ments for power standby times.
NOTE: UL Residential/Commer-
cial Burglary installations require
4Hrs Power Standby time.
NOTE: UL/ULC Residential Fire
& Home Care installations
require 24 Hr power standby.
ULC Commercial Burglary
and Fire monitoring installations
require 24 Hr power standby.

Standby Battery Guide

Battery Charging Current: 400 mA

Batt

Standby

Size

4Hr

24Hr

-------------------------------------------------
4Ahr

700mA

----

7Ahr

700mA

180mA

14Ahr

700mA

470mA

NOTE:

Replace batteries every 3-5 years.
Battery capacity will deteriorate with
age and number of charge/discharge
cycles

AC Wiring

UL Listed Installations
Primary:
120VAC/60Hz./0.33A
Secondary: 16.5VAC/40VA
DSCPTD 1640 Plug-in, Class 2
Transformer.

NOTE: Do not connect trans-
former to a receptacle controlled
by a switch.
(UL Listed Installations
Only)

RM-1/RM-2 POWER LOOP

SUPERVISORY RELAY

T-1

R-1
TIP

RING

RJ-31X

Tighten nut to break paint and make

good connection to the cabinet

This manual is related to the following products: