AEG 302D User Manual
Page 11
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

We strongly recommend the appliance is connected by a quali
fied electrician who is a member of the NICEIC who will comply
with the lEE and any local regulations.
NOTE:
The terminology “DOUBLE POLE” means that both the live
and neutral supplies are swiched and disconnected at the
same time.
The terminations labelled SUPPLY are for the connection for the
internal house wiring and the terminations labelled LOAD are for
the appliance.
IMPORTANT
The wires of the mains lead supplied with this appliance are
coloured in accordance with the following code:
Blue-Neutrai
Brown-Live
As the coiours of the flexible cord of this appliance may not
correspond with the coloured markings identifying the ter
minals in your plug, proceed as follows: The whire which is
coloured brown must be connected to the terminal which is
marked with the ietter L or coloured red.
The wire which is coloured blue must be connected to the
terminal which is marked with the letter N or coloured black.
Your appliance must be connected to fixed wiring via the use of
a double pole swiched fused spur outlet with or without pilot lamp.
Appliances
with 2 wires
---BLUE
(NEUTRAL)
BROWN
(LIVE)--
11