PLUG-IN MODULES

Sound Reinforcement — Modules MM-F & MM-S

Low-impedance, transformer-balanced microphone preampli­

fier module with HIGH-/LOW-CUT filters. GAIN control (25dB
range), phantom power. MM-F — female XLR-type connector;
MM-S — screw terminals (Terminal #1 is GND, #2 is LO, and
#3 is HI on all modules).
Operation

Phantom Power. Move PHANTOM P.S. jumper to the ON

position for +22V phantom supply. Select OFF position to
bypass.

Microphone Paoing - Module MP-S

Signal-activated low-impedance, transformer-balanced mic­

rophone preamplifier module with HIGH-/LOW-CUT filters,
GAIN control (25dB range). Automatic Level Control (ALC),
three levels of priority and phantom power are jumper selected.
Screw terminal connectors.
Operation

Phantom Power Move PH. P.S. jumper to ON position for

+ 22V phantom supply. Place jumper on either header pin to

bypass.

ALC:

Move ALC jumper to ON position; move to OFF to

bypass.

Milting Priority (using PRIORITY ASSIGN jumpers);

Level 1 — Place one jumper in the l"po.sition and store the

unused jumper on an empty pin.

Level 2 — Place both jumpers in the 2"position.

I.evel 3 — Place one jumper in the 3"position and store the

unused jumper on an empty pin.

Telephone Paging - Module TP-S

Signal-activated telephone paging module provides a 600-ohm

balanced input with -24dBm sensitivity for matching to telephone
page lines. Includes HIGH-/LOW-CUT filters and GAIN control

(25dB range). Automatic Level Control (ALC) and three levels of
priority are jumper-selected. Screw terminal connectors.

Operation

ALC:

Move the ALC jumper to ON position to enable ALC;

move to OFF position to bypass.

Muting Priority (using PRIORITY ASSIGN jumpers):

Level 1 — Place one jumper in the l"positioii and store the

unused jumper on an empty pin.

Level 2 — Place both jumpers in the 2"position.
Level 3 — Place one jumper in the 3”position and store the

unused jumper on an empty pin.

Auxiliary Input - Module BL-S

Transformer-balanced auxiliary input module suitable for line­

bridging or line-matching. Use the printed circuit board jumper to

select either 600-ohm input or 10-kilohm input. Screw terminal
connectors.

Line Output - Moduie LO-S

Module provides jumper-selected 600-ohm transformer-bal­

anced (+4dBm) output or 0.5-watt direct output at 8-ohms. May

be used for line output from the D-Series mixing bus or for

music-on-hold applications. Parallel RCA jacks permit one music
source to be used for M.O.H. and background music. A jumper-
selected pad provides 20dB attenuation of the signal from the
music source. LEVEL control sets the module output level.
Operation

Output Selection: Select DIRECT or XFMR-coupled output by

placing jumper J4 in the appropriate position. (When using
the direct output, connect the 8-ohm load between screw
terminals #1 and #3. When using transformer output, ter­

minal #1 is GND, #2 is LO, and #3 is HI.)
Place jumper J2 in L.O. position for line output or in M.O.H.
position for music-on-hold applications. Connect the music

source to the MUSIC IN (RCA) jack; the MUSIC OUT jack
is paralleled to allow same signal source to be used for back­
ground music.

Attenuator Pad: Place jumper J3 in the 20dB position to at­

tenuate the signal connected to the MUSIC IN jack. Bypass
the pad by placing the jumper in the OdB position.

Tone Signal Generation — Moduie TG-S

The module generates four distinct tones: CHIME, STEADY,

ALARM, and BURST. May be assigned to any of three levels of
priority. Requires customer-supplied contact closure between the

desired Tone and ENABLE screw terminal connectors.
Operation

Muting Priority (using PRIORITY ASSIGN jumpers):

Level 1 — Place one jumper in the l"position and store the

unused jumper on an empty pin.

Level 2 — Place both jumpers in the 2"position.
Level 3 — Place one jumper in the 3"position and store the

unused jumper on an empty pin.

Remote Volume Control or Compression — Module

VC-C

Dual-function (jumper-selected) compressor/remote volume

control module. The compressor limits the power amplifier input

signal to

1

volt to prevent overdrive.

Tlie DC-operated full range

volume control allows any output setting up to the maximum pre.set

on the D-Series unit MASTER level control.
Operation

Compression:

Set the

PRE/AMP LINK

switch on the D-Scries

unit to OUT position. Connect the PREAMP OUT jack on the
D-Series unit to the VC-C IN connector. Connect the VC-C
OUT jack to the AMP IN connector on the D-Series unit. Place

jumper J1 in the IN position to enable the compression func­

tion; move to the OUT position to bypass.

Remote Volume Control: Connect a potentiometer (minimum

value 20-kilohms) to terminals #1, #2, and #3.

FM Reception - Module

FM-T

FM tuner module designed as a preset background music

source. Screwdriver-adju.stcd tuning. The output is jumper-
selected to the mixing bus of the D-Series unit or to the module’s
RCA-type connector. May be configured to accept priority signals
from other modules. Monaural operation. Screw terminals for
antenna.
Operation

Output: Place jumper J1 in OUT position to assign tuner output

to the module’s RCA connector. Place jumper J1 in MIX BUS
position to assign module’s output to the D-Series mixing bus.

Mute: Place jumper J2 in the ON position to mute FM-T with

any level 2 or 3 priority signal. Place in OFF position to prevent
muting from priority signals.

MIC/Line Remote Control - Module MR-S

Low-impedance transformer-coupled MIC preamp, or line-

level module with HIGH-/LOW-CUT filters, GAIN control (25dB
range), phantom power. Full-range DC-operated full-range RVC
allows any output setting up to maximum preset on amplifier
channel control. Screw terminal connectors.
Operation

Input: Set Jumper J2 to MIC position for microphone input. Set

to LINE position for line level input.

Phantom Power Move jumper J1 to ON

position

for

-t-22V

phantom supply. Select OFF position to bj^ass.

Mute: Place jumper J3 in the ON position to mute MR-S with

any level 2 or 3 priority signal. Place in OFF position to prevent
muting from priority signals.

RVC: Connect RVC-D to terminals 1 and 4.