TECHNICAL SPECIFICATIONS
Output Rating
Transformer
Direct
+4dBm,
600
onms (Rated), +l6dBm,
600
ohms (Maximum)
+6dBm, 600 ohms (Rated), +18dBm, 600 ohms (Maximum)
Frequency Response
20Hz-20,000Hz, +0,-1dB
Distortion
<0.2% @ Maximum Output (Over a Power Bandwidth of
2OHz-20,OOOHz, +0,-1dB), <0.01% Typical
Signai-to-Noise Ratio
72dB with MASTER @ Maximum
Input Sensitivity/Impedance
Module Inputs
1(X)mV/10 kilohms
Program Input
100mV/10 kilohms
Bridqing I/O
100mV/3 kilohms
Tone Controls
Bass
±10dB@ 100Hz
Treble
±10dB@ 10kHz
Program Variable Mute Range
60dB (Minimum)
Power Requirements
120VAC,eOHz
Dimensions
5-1 /2"H
X
16-1 /2"W
X
11-3/8“D
OPERATION
POWER
The front-panel rocker switch applies power to the mixer. An
integral pilot lamp illuminates when power has been applied.
LEVEL CONTROL
Set gain and filter controls on modules so equipped to mid
rotation. Set the mixer (CHANNEL 1 through 6) level controls to
their full counterclockwise position. Control the level of each input
on the desired bus (A or B) with clockwise rotation of the ap
propriate control. The overall output level is adjusted with the
appropriate MASTER control.
The
T.F.D level meter
will il
luminate red to indicate possible signal clipping conditions.
TONE CONTROL
When the Tone Control switches in the module cage are in the
OUT position, the front panel tone controls are disabled and the
tone response will be flat. To enable the front panel tone controls
for either bus, set the appropriate A or B control switch to the IN
position. Bass and treble tone controls provide ± lOdB cut/boost
at lOOHz and lOkHz, respectively.
VARIABLE MUTE
Operation of the variable-mute feature (0 to 60dB range)
requires a customer-supplied contact closure across the MUTE
terminals. This contact closure will mute the program input (PGM)
and any module set to priority level 1 or 2.
MAINTENANCE
Caution
There are no user-servieahle parts within the unit. Refer all
servicing to qualified sen’ice personnel
AC CIRCUIT BREAKER
If the AC circuit breaker trips, the power switch pilot lamp will
go out and there will be no output. Set the AC power switch to
OFF and depre.ss the red button on the circuit breaker to reset it.
Return the
AC
power switch to
ON. Tf
the breaker trips again, have
the trouble Investigated by a qualified technician.
THERMAL BREAKER
The thermal breaker will open when the temperature at the
output transistor heat sink reaches 105°C (221°F) on all models. If
the breaker opens, there will be no output but the power switch
pilot lamp will remain illuminated. Wait approximately two min
utes for the breaker to reset. If the breaker resets and then opens
again, investigate the cause of the temperature overload. This may
be due to improper connections at the output terminals or excessive
environmental heat with inadequate ventilation.
SERVICE
We are interested in the maintenance of your Bogen equip
ment. If you encounter difficulty, do not hesitate to ask our advice.
Information can be obtained by writing to Service Department,
Bogen Communications Inc., P.O. Box 575, Ramsey, NJ 07446.
When communicating with us, give the model and series desig
nation (stamped on the rear panel) of your unit. Describe the
difficulty and include details on the electrical connection to as
sociated equipment. We will send you service information if the
trouble appears simple. If the amplifier requires servicing, we will
send you the name and address of the nearest Bogen Service
Agency to which you can send the unit for repairs.
When shipping the unit, pack carefully to prevent damage in
transit. Send the unit, insured and freight prepaid, via any respon
sible carrier. The unit
will
be promptly repaired and returned
to
you collect (freight prepaid while in warranty).