beautypg.com

Technical specifications, Operation, Maintenance – Bogen DMP-06 User Manual

Page 2

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

TECHNICAL SPECIFICATIONS

Output Rating

Transformer

Direct

+4dBm,

600

onms (Rated), +l6dBm,

600

ohms (Maximum)

+6dBm, 600 ohms (Rated), +18dBm, 600 ohms (Maximum)

Frequency Response

20Hz-20,000Hz, +0,-1dB

Distortion

<0.2% @ Maximum Output (Over a Power Bandwidth of

2OHz-20,OOOHz, +0,-1dB), <0.01% Typical

Signai-to-Noise Ratio

72dB with MASTER @ Maximum

Input Sensitivity/Impedance

Module Inputs

1(X)mV/10 kilohms

Program Input

100mV/10 kilohms

Bridqing I/O

100mV/3 kilohms

Tone Controls

Bass

±10dB@ 100Hz

Treble

±10dB@ 10kHz

Program Variable Mute Range

60dB (Minimum)

Power Requirements

120VAC,eOHz

Dimensions

5-1 /2"H

X

16-1 /2"W

X

11-3/8“D

OPERATION

POWER

The front-panel rocker switch applies power to the mixer. An

integral pilot lamp illuminates when power has been applied.

LEVEL CONTROL

Set gain and filter controls on modules so equipped to mid­

rotation. Set the mixer (CHANNEL 1 through 6) level controls to
their full counterclockwise position. Control the level of each input
on the desired bus (A or B) with clockwise rotation of the ap­
propriate control. The overall output level is adjusted with the

appropriate MASTER control.

The

T.F.D level meter

will il­

luminate red to indicate possible signal clipping conditions.

TONE CONTROL

When the Tone Control switches in the module cage are in the

OUT position, the front panel tone controls are disabled and the
tone response will be flat. To enable the front panel tone controls
for either bus, set the appropriate A or B control switch to the IN
position. Bass and treble tone controls provide ± lOdB cut/boost

at lOOHz and lOkHz, respectively.

VARIABLE MUTE

Operation of the variable-mute feature (0 to 60dB range)

requires a customer-supplied contact closure across the MUTE
terminals. This contact closure will mute the program input (PGM)
and any module set to priority level 1 or 2.

MAINTENANCE

Caution

There are no user-servieahle parts within the unit. Refer all

servicing to qualified sen’ice personnel

AC CIRCUIT BREAKER

If the AC circuit breaker trips, the power switch pilot lamp will

go out and there will be no output. Set the AC power switch to
OFF and depre.ss the red button on the circuit breaker to reset it.

Return the

AC

power switch to

ON. Tf

the breaker trips again, have

the trouble Investigated by a qualified technician.

THERMAL BREAKER

The thermal breaker will open when the temperature at the

output transistor heat sink reaches 105°C (221°F) on all models. If
the breaker opens, there will be no output but the power switch

pilot lamp will remain illuminated. Wait approximately two min­

utes for the breaker to reset. If the breaker resets and then opens

again, investigate the cause of the temperature overload. This may
be due to improper connections at the output terminals or excessive
environmental heat with inadequate ventilation.

SERVICE

We are interested in the maintenance of your Bogen equip­

ment. If you encounter difficulty, do not hesitate to ask our advice.
Information can be obtained by writing to Service Department,
Bogen Communications Inc., P.O. Box 575, Ramsey, NJ 07446.

When communicating with us, give the model and series desig­

nation (stamped on the rear panel) of your unit. Describe the
difficulty and include details on the electrical connection to as­
sociated equipment. We will send you service information if the
trouble appears simple. If the amplifier requires servicing, we will
send you the name and address of the nearest Bogen Service
Agency to which you can send the unit for repairs.

When shipping the unit, pack carefully to prevent damage in

transit. Send the unit, insured and freight prepaid, via any respon­

sible carrier. The unit

will

be promptly repaired and returned

to

you collect (freight prepaid while in warranty).