Clarke CFP-2000DS User Manual
Page 26
Page -26 -
Clarke
®
Operator's Manual
- CFP Polisher
TROUBLESHOOTING
SWIRLS ON THE FLOOR AFTER SCRUBBING
•
Floor not clean.
•
Incorrect solution.
•
Area not properly swept - debris in pad or brush.
•
Improper pad or brush for the job.
•
Moving the machine too fast.
SWIRLS ON THE FLOOR AFTER DRY BUFFING
•
Moving the machine too fast.
•
Floor finish too soft.
•
Area not properly swept - debris in pad or brush.
•
Improper pad or brush for the job.
CIRCLES ON THE FLOOR
•
Machine standing still while the brush or pad is
running.
FLOOR FINISH REMOVED
•
Improper pad... too aggressive.
•
Solution too strong.
MACHINE WOBBLES DURING OPERATION
•
Defective pad... one side is more dense than the
other.
•
Machine left sitting on brush or pad for extended
period of time causing bristles or pad to “take a
set”.
•
Pad not “seated” properly into pad holder
bristles.
•
Warped block on brush or padholder - replace.
MACHINE DOES NOT RUN
•
Check plug for proper connection - on machine
and at wall outlet.
•
Check building circuit breaker.
•
Call for service.
LIGHT ON 2000DS MOTOR ILLUMINATES
•
Stop operating machine within 6 hours
•
Call for service
•
Replace carbon motor brushes.