TROUBLESHOOTING

SWIRLS ON THE FLOOR AFTER SCRUBBING

Floor not clean.

Incorrect solution.

Area not properly swept - debris in pad or brush.

Improper pad or brush for the job.

Moving the machine too fast.

SWIRLS ON THE FLOOR AFTER DRY BUFFING

Moving the machine too fast.

Floor finish too soft.

Area not properly swept - debris in pad or brush.

Improper pad or brush for the job.

CIRCLES ON THE FLOOR

Machine standing still while the brush or pad is
running.

FLOOR FINISH REMOVED

Improper pad... too aggressive.

Solution too strong.

MACHINE WOBBLES DURING OPERATION

Defective pad... one side is more dense than the
other.

Machine left sitting on brush or pad for extended
period of time causing bristles or pad to “take a
set”.

Pad not “seated” properly into pad holder
bristles.

Warped block on brush or padholder - replace.

MACHINE DOES NOT RUN

Check plug for proper connection - on machine
and at wall outlet.

Check building circuit breaker.

Call for service.

LIGHT ON 2000DS MOTOR ILLUMINATES

Stop operating machine within 6 hours

Call for service

Replace carbon motor brushes.