Mounting the controller outdoors (mpc), Mounting the controller outdoors (mpc enclosure) – Hunter SRC User Manual
Page 9
4
5
MOUNTING THE CONTROLLER OUTDOORS (MPC ENCLOSURE) ..................................
1. The MPC enclosure has 4 mounting holes, 3 along the top of the
unit, and one at the bottom center. These may be punched out in
order to secure the unit to a wall.
2. Remove the door and mounting plate from the SRC. Attach the SRC
to the MPC by inserting the mounting tab on the mounting plate
inside the MPC, into the keyhole in the back of the SRC. Slide down
the SRC until it locks into place. You may use an optional mounting
screw if desired.
3. Field wiring should be routed through the large center hole in the
enclosure using an appropriate conduit and conduit fitting.
NOTE: Installation of the primary voltage
wires should be done by a licensed electrical
professional. Improper installation may result in
fire or shock hazard.
MPC Enclosure
4. With primary power off, the primary power wires should be routed
through an agency approved electrical conduit and electrical
conduit fitting into the duplex outlet wiring enclosure and attached
to the outlet.
5. The transformer may then be plugged into the duplex outlet.
6. Attach the two wires coming out of the transformer to the two screw
slots on the SRC labeled “AC.”
7. Primary power may now be turned on.