9800 configuration settings, Dip switches and jumpers – Cal Spas LTR20051000 User Manual
Page 73

Appendix
9800 Configuration Settings
WARNING! SHOCK HAZARD!
There are no user serviceable parts. DO NOT attempt service of this control system. Contact your dealer or
service center for service.
DIP Switches and Jumpers
Note: Switchbank B is totally disabled.
A1 Test
mode
OFF
A7 N/A
A2 Add 1 pump with heat
A8 N/A
A3 Add 2 pumps with heat
A9 N/A
A4 N/A
A10 No
edit
A5 N/A
A11 N/A
A6 N/A
A12 Memory
ON
A1 Test
mode
OFF
A7 N/A
A2 Add 1 pump with heat
A8 N/A
A3 Add 2 pumps with heat
A9 N/A
A4 Add 3 pumps with heat
A10 No edit
A5 N/A
A11 N/A
A6 N/A
A12 Memory
ON
A1 Test
mode
OFF
A7 N/A
A2 Add 1 pump with heat
A8 N/A
A3 Add 2 pumps with heat
A9 N/A
A4 N/A
A10 No
edit
A5 N/A
A11 N/A
A6 N/A
A12 Memory
ON
DIP Switch Key
A1
Test mode (normally off)
A2
In ON mode, add one high-speed pump (or blower) with heater
A3
In ON mode, add two high-speed pumps (or one high speed pump and blower) with heater
A4
In ON mode, add four high-speed pumps (or three high speed pumps and blower) with heater
A5—A9 N/A
A10
When switched on when spa is on, system will enter the Edit Menu for configuration settings. Do
not start the spa with A10 turned on or a CFE error will occur. (CFE errors are illegal configurations
such as a pump and blower set to run on the same output. The configuration must be corrected
before the spa will operate.
A11 N/A
A12
Persistent memory reset (used when spaq is powering up)
Note: A2, A3, and A4 work in combination. Example: A2 and A3 in the ON position and A4 in the OFF
position will allow 3 high speed pumps (or two high speed pumps and the blower) to run with the heater.
2005 Spa Owner's Manual
Page 69
8/1/2005