Content s, Figure 3-6. device wiring, Po wer ra ting – CPG FIRELARM 2500 CPG #2561255 User Manual
Page 20: Tb2 tb1a 19, Zone 4, Bell 2, Auxiliar y alarm, Auxiliar y tr ouble remo te st a tion e gnd, Zone 1, Zone 2

Content
s
1
2
3
CPG #2561255
F
IRE
L
ARM
2500 Operating Manual
3-6
PO
WER RA
TING
120V
A
C
- 60 HZ
(2) 12V
, 6.5 AH min.
batter
ies are required.
Maxim
um batter
y charge current:
1A
The batter
y set m
ust be replaced e
v
er
y 4 y
ears or ear
lier if capacity is
e
xcessiv
ely reduced.
The batter
ies should be chec
k
ed at least twice a
y
ear
, or more often if required b
y
local codes
.
SEE ZONES 1 AND 2 AND BELL 1
FOR TYPICAL
CONNECTIONS
5.1K
TB2
TB1A
19
(+)
20
(+)
21
(-)
22
(-)
(+)
(+)
(-)
(-)
5.1K
5.1K
N.O
.
COM
N.C
.
N.O
.
COM
N.C
.
23
(+)
29
(+)
30
(-)
31
(-)
(+)
(+)
(-)
(-)
32
(+)
33
34
24
25
26
27
28
(-)
(+)
(-)
(-)
(+)
(+)
(-)
38
39
40
35
36
37
(+)
(-)
(+)
42
43
44
41
ZONE 3
(SUPER
VISED)
ZONE 4
(SUPER
VISED)
BELL 2
(SUPER
VISED)
A
UXILIAR
Y
ALARM
(NO
T SUPER
VISED)
USE PO
WER LIMITED
CIRCUITS ONL
Y
.
A
UX.
CONT
A
CTS RA
TED
2A @ 30VDC
0.6 PO
WER F
A
CT
OR
TYPICAL
STYLE
Y (CLASS B)
WIRING
USE POLARIZED
DEVICES ONL
Y
24VDC 2A MAX
A
UXILIAR
Y
TR
OUBLE
REMO
TE ST
A
TION
E
GND
SECOND
AR
Y
WINDING OF
TRANSFORMER
BA
TT
TB1
TB4
P2
TRANSFORMER
CONNECT
OR
BA
TTER
Y
CONNECT
OR
(SUPER
VISED)
ZONE 1
(SUPER
VISED)
ZONE 2
(SUPER
VISED)
SUPER
VISOR
Y
(SUPER
VISED)
BELL 1
(SUPER
VISED)
24VDC
SEE NO
TE 6
24VDC .015A MAX
EA
CH CIRCUIT
ALARM
RA
(SUPER
VISED*)
SUPER
VISOR
Y
RS
(SUPER
VISED*)
4-WIRE
DET
. PWR
(SUPER
VISED)
A
UX.
PWR
REMO
TE ANNUNCIA
T
O
R
(SUPER
VISED)
(2 MAX, 100mA PER UNIT)
TYPICAL
STYLE D (CLASS A)
WIRING
USE N.O
. SUPV
SWITCHES
INTENDED FOR
CONNECTION T
O
A
POLARITY REVERSAL
CIRCUIT OF A REMO
T
E
ST
A
TION RECEIVEING
UNIT THA
T
HAS
COMP
A
TIBLE RA
TINGS
.
AN ECLIPSE MODEL F
A24VB
MUST BE USED ON REMO
TE
ST
A
TION CIRCUITS
.
*
THE REMO
TE ST
A
TION
MUST PR
O
VIDE
SUPER
VISION
REMO
TE ANNUNCIA
T
O
R
TYPICAL
STYLE B (CLASS B)
WIRING
5.1K
5.1K
5.1K
290-0008
D
D
*
GND
+24V
EAR
TH
(OPTIONAL)
(+)
(-)
34
56
78
9
1
0
1
1
1
2
1
3
1
4
1
5
1
6
1
7
1
8
E
34
PO
WER LIMITED
All circuits po
w
ered b
y
this panel are po
w
er limited.
T
ransf
or
mer
, batter
y,
auxiliar
y alar
m and auxiliar
y troub
le
connections are not po
w
er limited.
NO
TES:
1)
Use only smok
e detectors that are listed in compatibility listing in o
wner's man
ual.
2)
An
y z
one (e
xcept super
visor
y z
one) can be oper
ated in a Style D (Class A) mode
.
The
end-of-line resistor is in the panel when Class A mode is used.
3)
Lea
v
e
end-of-line test resistors on un
used circuits
.
4)
Combined load of all e
xter
nal de
vices
, including indicating appliances
, is not to e
xceed
2.5A.
5)
P
olar
ities sho
wn are f
or nor
mal standb
y condition.
Bell and remote station circuits
re
v
erse polar
ity when activ
ated.
6)
Combined load of remote ann
unciator
, 4-wire detectors
, and auxiliar
y po
w
er (ter
minals
17, 18, 42, 43, and 44) is not to e
xceed .5A.
7) All EOL resistors are 5.1K ohms (#024-4556)
Figure 3-6. Device Wiring