Error messages, Teac corporation – Tascam DA-88 User Manual
Page 26
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
In the Analog output mode, the analog outputs are timed to compensate for the D/A conversion time as well as the
anticipatory A/D conversion time (42 samples in total as shown). But this in turn disturbs the digital output
timing. On the other hand, in the Digital output mode, the analog outputs will lag because this mode disables tbe
compensation circuit so that the digital outputs are timed as it should.
oo
42Fs
A OUT
A IN
D OUT
D IN
OO
MASTER
SLAVE
Error Messages
. L L. U L •
No clock is coming in. Or, the CLOCK switch is not set to
match an incoming clock. Check also if the slave machines
(ID-numbered 1-15) are correctly connected in series through
their SYNC IN/OUT connectors, and if the master is ID-
numbered 0.
E.L.c u t:
The tape has broken. The only remedy is replacement of the
tape.
E.d I o :
The DIGITAL I/O port is accidentally unplugged.
E.d E :
Condensation occurred on the head drum. Leave the machine for
1 or 2 hours with the power switched on until it stabilizes at the
temperature of its operating environment.
E.H I - 8. E '■
A different tape from the Hi8 is inserted. Use Hi8 tapes only.
E.Eh I n.E :
The tape inserted is too thin (less than 8 pm). Use P6/E6-120
(or P5/E5-90) or shorter tapes.
5 - E r r 8
This shows the incident of error in the mechanics (the "8" is
variable).
If this message appears, switch the power off, then switch it on
again. If the message does not go out, repeat the on/off
switching or try ejecting and reinserting the tape several times.
If all attempts are of no avail, please contact TASCAM or your
nearest TASCAM dealer.
WARNING LED
This indicator lights to indicate the following :
o Condensation on the head drum
o Tape has broken
o DIGITAL I/O port accidentally disconnected
o External clock not coming in correctly
o No time code plugged in (when the optional SY-88 is
installed)
o Time code setting not matched the type of incoming code
(when the optional SY-88 is installed)
If the indicator lights, check to see whether error messages
specify the problem in the display.
TEAC CORPORATION
Musashino Center Bldg., 1-19-18, Nakachb, Musashino-shi, Tokyo 180, Japan Phone: (0422) 52-5081
TEAC AMERICA, INC.
7733 Telegraph Road, Montebello, California 90640 Phone: (213) 726-0303
TEAC CANADA LTD.
340 Brunei Road, Mississauga, Ontario L4Z 2C2, Canada Phone: 905-890-8008
TEAC UK LIMITED
5 Marlin House, Marlins Meadow, The Croxley Centre, Watford, Herts. WD1 8YA, U.K. Phone: 0923-819631
TEAC DEUTSCHLAND GmbH
Bahnstrasse 12, 65205 Wiesbaden-Erbenheim, Germany Phone: 0611-71580
TEAC FRANCE S.A.
17. Rue Alexis-de-Tocqueville, CE 005 92182 Antony Cedex, France Phone: (1) 42.37.01.02
TEAC BELGIUM NV/SA
143C Woluwelaan, 1831 Machelen-Diegem, Belgium Phone: (02) 725 6555
TEAC NEDERLAND BV
Perkinsbaan 11,3439 ND Nieuwegein, Nederland Phone: 03-402-30229
TEAC AUSTRALIA PTY, LTD.
A.C.N. 005 408 462
106 Bay Street, Port Melborne, Victoria 3207, Australia Phone: (03) 646-1733
TEAC ITALtANA S.p.A.
Via C. Cantu 5, 20092 Cinisello Balsamo, Milano, Italy Phone: 02-66010500
PRINTED IN JAPAN 0498U1 M-0788J