Figure 8, Cleaning impeller, Cleaning shallow well jet – Sears 390.252158 User Manual
Page 9: Maintenance
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
MAINTENANCE
4. Place back half of pump on flat surflice and tap out ce
ramic seat. See Figure 6.
I. Screw impeller on shaft (clockwise) while holding
shaft with 7/l6” open end wrench on shaft fiats. This
will automatically locate seal in place. See Figure 8.
Figure 6
5. Clean seal cavity.
6. Install new seal.
A. Clean polished surface of ceramic seat with clean
cloth.
B. Wet outer edge of “O” Ring with deteigent solution.
C. With finger pressure press seat firmly and squarely
into cavity. See Figure 7A. Polished face of seat faces
inside of pump. If seat will not locate properly, place
cardboard washer over polished face and use piece of
3/4” standard pipe for pressing purposes. See Figure
7B.
Figure 7A
Figure 7B
D. Dispose of cardboard washer and clean surface of
seat,
E. Clean motor shaft.
F. Reassemble back half of pump to motor. '
G. Apply detergent solution to inside diameter of rotat
ing seal member.
H. Slide rotating member on shaft until rubber drive ring
hits shaft shoulder. NOTICE: BE SURE you do not chip
or scratch seal face on shaft shoulder or seal will leak!
^ y
478 0194
Figure 8
J. Remount diifuser on seal plate.
Cleaning Impeller
1, Follow steps lA through IE under “Disassembly and
Assembly of Pump” on Page 8.
2. Remove diffuser and impeller from pump per instruc
tions under “Removing Motor for Service and Replacing
Shaft Seal” on Page 8.
3- Clean impeller and reassemble impeller and diffuser f>er
instructions under “Removing Motor for Service and
Replacing Shaft Seal” on Pages 8 and 9-
Cleaning Shallow Well Jet
To remove debris from venturi or nozzle, proceed as fol
lows:
1. Disassemble pump per instructions on Page 8.
2. Turn venturi counterclockwise and remove it. The noz
zle is now exposed. Remove it using a 5/8” hex socket
wrench with extension. Turn counterclockwise. If
socket wrench is not available, insert an ice pick or sim
ilar pointed tool carefully into the nozzle. TTiis wiU dis
lodge debris.
3- Flush out the debris by running water through the noz
zle in the same direction as the dislodging tool was in
serted.
4. Reinstall nozzle and venturi. Do not overtighten!
5. Reassemble pump per instructions on Pages 8 and 9.