beautypg.com

Ik danger, Operating procedures, Warning – Sears Craftsman 919.154320 User Manual

Page 8

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

Groynding Instryctions

WAiNING

1

iMPROPER GROUNDING CAN RESULT M
ELECTRICAL SHOCK. !N THE EVENT OF A

SHORT CIRCUIT, GROUNDING REDUCES
THE RISK OF SHOCK BY PROVIDING AN
ESCAPE WIRE FOR THE ELECTRIC CUR­
RENT. THIS AIR COMPRESSOR MUST BE
PROPERLY GROUNDED.

1. The air compressor is equipped with a cord having a

grounding wire with an appropriate grounding plug.
The plug must be used with an outlet that has been
installed and grounded in accordance with all local
codes and ordinances. The outlet must have the
same configuration as the plug. DO NOT USE AN

ADAPTER.

2. Do not modify the plug that has been provided. If it

does not fit the available outlet, the correct outlet
should be installed by a qualified electrician.

3. Inspect the plug and cord before each use. Do not use

if there are signs of damage.

ik DANGER

RISK OF ELECTRICAL SHOCK. IF REPAIR­
ING OR REPLACING CORD OR PLUG, THE
GROUNDING WIRE MUST BE KEPT SEPA­
RATE FROM THE CURRENT-CARRYING
WIRES. NEVER CONNECT THE GROUND­
ING WIRE TO A FLAT BLADE PLUG TER­
MINAL.

(THE

GROUNDING

WIRE

HAS

INSULATION WITH AN OUTER SURFACE

THAT IS GREEN -- WITH OR WITHOUT YEL­

LOW STRIPES.)

If these grounding instructions are not completely
understood, or if in doubt as to whether the compressor
is properly grounded, have the installation checked by a
qualified electrician.

Plug

Jj

Ground

White

Wire

Outlet

120 volts, 15 amps

Break-In Procedures

[

CAUTION

Serious damage may result if the following
break-in

instructions

are

not

closely

followed.

This procedure is only required the first time the air com­

pressor is put into service.

1. Set the pressure switch OFF/AUTO lever to the “OFF”

position.

2. Plug the power cord into the correct branch circuit

receptacle.

3. Turn the regulator clockwise, opening it fully, to pre­

vent air pressure build-up in the tank.

4. Move the OFF/AUTO lever to “AUTO". The compres­

sor will start.

5. Run the compressor for 10 minutes. Make sure the

regulator is open and there is no tank pressure build­
up.

6. After 10 minutes, close the regulator by turning it

counter-clockwise. The air tank will fill to cut-out pres­
sure and then the motor will stop.

OPERATING PROCEDURES

1. Before attaching air hose or accessories, make sure

the OFF/AUTO lever is set to “OFF” and the air

regulator is closed. (Close it by turning it counter­

clockwise.)

2. Attach hose and accessories.

WARNING

]

TOO MUCH AIR PRESSURE CREATES A

HAZARDOUS RISK OF BURSTING. CARE­
FULLY FOLLOW STEPS 3 AND 5 EACH TIME

THE COMPRESSOR IS USED.

[

CAUTION

COMPRESSED AIR FROM THE OUTFIT MAY
CONTAIN WATER CONDENSATION. DO

NOT SPRAY UNFILTERED AIR AT AN ITEM

THAT COULD BE DAMAGED. SOME AIR
OPERATED TOOLS OR DEVICES MAY

REQUIRE

FILTERED

AIR.

READ

THE

INSTRUCTIONS FOR THE AIR TOOL OR
DEVICE.

3. Check the manufacturer’s maximum pressure rating

for air tools and accessories. The regulator outlet

pressure must never exceed the maximum pressure
rating.

This manual is related to the following products: