Sears 919.17632 User Manual
Page 5
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
HAZARD
SAFEGUARDS
Toxic Vapors
Compressed air from Ihfs unit
may
con^in
poisonous
carbon
monoxide.
Never directly inhale the compressed air
produced by this unit.
Certain
sprayed
materials
such
as paints, weed killer, sand, in
secticides, etc., may be harmful if
used in a closed area or if inhaled.
Be certain to read labels when spraying
paints or poisons.
Use a mask or respirator whenever thera is a
chance that you might inhale anything that
you are spraying. Read all instructions so
that you know that your mask will protect you
from what you are spraying.
Compressed Air
Compressed air may propel dirt,
metal shavings, etc. and result in
possible injury.
Never point any nozzle or sprayer lowanl a
person or any part of the body.
Always wear safety goggles or glasses when
spraying.
SPEaFlCATION CHART
Model No.
919.176210
919.176311 .
919.176320
919.176330
HP
1
1
2
3
Displacement CFM
9.2
9-2
11.7
14XÌ
Bore
2%"
2%"
2%"
Z%"
Stroke
2"
2"
2"
2"
Voltage-Single Phase
'110-220
’110-220
220-240
220-240
Branch Circuit Min. Requirements
20 amp
15 amp
15 amp
15 amp
’Fuse Type
“Fusetran" Type T
"Fusetron’TypeT
"Fusetron" Type T
"Fusetron" Type T
Amperage at Max Pressure
19.5
15.5
12.4
14.4
Air Tank Capacity
12 gal
12 gal ASME
20 gal ASME
30 gal ASME
Approximate Cut-in Pressure
-80' psig
80 psig
100 psig
100 psig
Approximate Cut-out Pressure
100 psig
100 psig
125 psig
125 psig
SCFM at 125 psig
—
—
6.4
75
too psig
5.6
5.6
—
90 psig
6.0
6.0
7.5
8.5
40 psig
7.3
73
9.0
10.3
*Models9l9.i76210&9Tai76311,
1
HP motor is duai voltage, 110-120 and 220-240 vott. It is wired forllO-120 volt but can be converted to
220-240 volt operation. Instructions for connecting the motor for operation at 220-240 volt can be found printed on the Inside of the
motor cover or on the nameplate of motor.
*A circuit breaker is also acceptable.
CAUTION
MCH3EL #91^176311 (1 HP) efr Compressor ean be oper
ated on a IS amp efreult provided the following conditions
exist:
1) Voltage supply to circuit is normal,
2) Circuit Is not utmd to supply any other electrical needs
(appliances, lights, etc,)
3) Extension cords comply with speclflcatlona in manual.
4) Circuit Is equipped with 15 №ip circuit breaker or 15
amp 'Tusetron” Type T time delay fuse.
If any of the above conditions cannot be met or If ttie
operation of the compressor repieatedly cause Interrup
tion of the poviwr It msy be necessary to operate It from a
20 amp circuit.
CAUTION
Vivien converting 1 HP models to 220-240 volt operation,
the attached three-prong
110-120
volt plug must be
replaced with a three-prong 220-240 volt plug (purchase
locally) or order line cord Part No. SUOL-404-1.
SCFM (Standard Cubic Feet per Minute);
Unit of measure of air delivery
PSIG (Pounds per Square Inch Gauge):
Unit of measure of pressure