C. starter rope repair and replacement – Sears 358.356090-3.7/20" User Manual
Page 20
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
![background image](/manuals/718035/20/background.png)
e.
Blow out loosened carbon with com
pressed air.
f.
Clean the spark arrestor screen with a
wire brush or replace if breaks in the
screen are found.
g. Reassemble muffler parts.
SPARK PLUG
• Maintenance is indicated when the engine
is hard to start.
• Keep the spark plug:
—clean
—properly gapped (.025”)
Items Required: Small brush, such as a
tooth brush, or a pocket knife.
a. Remove the carburetor cover.
b.
Pull the rubber connector from the
spark plug and remove the spark plug
from the cylinder.
c.
Clean deposits from the electrodes of
the spark plug with a small brush or a
pocket knife.
NOTE: Be careful when removing,
cleaning, gapping and replacing the
spark plug. If it is damaged, it will not
work properly and must be replaced.
d.
Set the gap between the electrodes to
.025 using a wire or flat gauge. Figure
47.
e.
Replace the spark plug in the cylinder
and attach the rubber connector.
f.
Replace carburetor cover and knob.
C. STARTER ROPE REPAIR AND REPLACEMENT
•
A starter rope that breaks next to the pulley
can be repaired.
•
Replace a starter rope that breaks more than
2 or 3 Inches from the pulley.
WARNING!
Always wear eye protection when ser
vicing the starter rope. The recoil
spring beneath the pulley is under ten
sion. If the spring should pop out seri
ous personal injury could result.
NOTE: The recoil spring, located beneath the
pulley, is under tension.
If spring pops out, it
will require considerable time and effort to
reinstall.
For this reason, you may want to let
your Sears Service Center handle this repair.
If you do try to repair the starter rope and the
recoil spring pops out, take the unit to your
Sears Service Center.
1. Remove the four screws on the side of the
fan housing. Figure48.
NOTE: Notice the different lengths of the
screws and their proper locations while
removing the screws.
2. Remove the fan housing.
3. If the starter rope is not broken, release the
spring tension by pulling about12 inches of
rope from the pulley and catch the rope in
the notch as shown. Figure
49
.
NOTE: The tension on the starter spring will
be released if the rope has broken.
4. Turn the pulley counterclockwise until the
spring tension is released.
Figure 49