INSTALLATION

Continued

WARNING: This appliance

is equipped for (natural or pro-
pane/LP) gas. Field conversion
is not permitted.

INSTALLATION AND CLEARANCES

(Vent-Free Operation Only)

WARNING: Maintain the

minimum clearances. If you can,
provide greater clearances from
floor, ceiling, and adjoining wall.

MINIMUM FIREPLACE CLEARANCE

TO COMBUSTIBLE MATERIALS

Side Wall 16"

Ceiling: 42"

LOG SIZING REQUIREMENTS

Minimum Firebox

Log

Front

Rear *

Size

Height

Depth

Width

Width

18"

17"

13"

28"

20"

24"

17"

13"

28"

21"

30"

17"

13"

34"

24"

* Measured at 13" depth.
Carefully follow the instructions below. This will
ensure safe installation into a masonry, UL127-
listed manufactured fireplace, or listed vent-free
firebox.

Minimum Clearances for Side
Combustible Material, Side Wall, and
Ceiling
A. Clearances from the side of the fireplace cabi-

net to any combustible material and wall
should follow diagram in Figure 4.
Example:

The face of a mantel, bookshelf,

etc. is made of combustible material and pro-
trudes 3

1

/

2

" from the wall. This combustible

material must be 4" from the side of the fire-
place opening (see Figure 4).
Note:

When installing your gas logs into a

manufactured firebox, follow firebox
manufacturer’s instructions for minimum
clearances to combustible materials.

B. Clearances from the top of the fireplace open-

ing to the ceiling should not be less than 42
inches.

Figure 4 - Minimum Clearance for

Combustible to Wall

*Minimum 16 inches from Side Wall

*

Example

NOTICE: Manual control heaters
may be used as a vented prod-
uct. If so, you must always run
heater with chimney flue damper
open. If running heater with
damper open, noncombustible
material above fireplace open-
ing is not needed. Go to

Install-

ing Damper Clamp Accessory for
Vented Operation, page 11.

Minimum Noncombustible Material
Clearances

If Not Using Mantel
Note:

If using a mantel, proceed to If Using Mantel.

If not using a mantel, follow the information below.
You must have noncombustible material(s) above the
fireplace opening. Noncombustible materials (such
as slate, marble, tile, etc.) must be at least 1/2 inch
thick. With sheet metal, you must have noncombus-
tible material behind it. Noncombustible material
must extend at least 8" up (for all models). If non-
combustible material is less than 12", you must in-
stall the fireplace hood accessory (24" and 30" mod-
els only). See Figure 5 for minimum clearances.
IMPORTANT:

If you cannot meet these minimum

clearances, you must operate heater with chim-
ney flue damper open. Go to Installing Damper
Clamp Accessory for Vented Operation,
page 11.