Installation, Continued, Floor clearances – Desa Tech CCL3018NR User Manual

Page 11

background image

www.desatech.com

111161-01D

11

Minimum
Noncombustible
Material

8"
Min.

12"

15"

18"

All minimum
distances are
in inches

Log Set
18", 24",
30" Models

20"

2

1

/2

"

6"

8"

10"

12"

Distances to
Underside of
Mantel

Hood
(GA6050,
GA6052)

Top of
Fireplace
Opening

Underside
of Mantel
Shelf

Mantel Shelf

INSTALLATION

Continued

Figure 7 - Minimum Mantel Clearances

When Using Hood

All
Models

NOTICE: If your installation does
not meet the minimum clear-
ances shown, you must do one
of the following:
• operate the logs only with the

flue damper open

• raise the mantel to an accept-

able height

• remove the mantel.

FLOOR CLEARANCES

A. If installing appliance on the floor level, you

must maintain the minimum distance of 14"
to combustibles (see Figure 8).

B. If combustible materials are less than 14" to

the fireplace, you must install appliance at
least 5" above the combustible flooring (see
Figure 9).

14"
Min.

Combustible
Material

Noncombustible Material

Hearth

5"
Min.

Combustible
Material

Figure 9 - Minimum Fireplace Clearances

Above Combustible Flooring

Figure 8 - Minimum Fireplace Clearances

If Installed at Floor Level

INSTALLING DAMPER CLAMP
ACCESSORY FOR VENTED
OPERATION

Note:

When used as a vented heater, appliance

must be installed only in a solid-fuel burning fire-
place with a working flue and constructed of non-
combustible material.
If you choose to use your heater as a manually-
controlled model (no remote control installed), you
may use this heater as a vented product. There are
three reasons for operating your heater in the
vented mode.
1. The fireplace does not meet the clearance to

combustibles requirements for vent-free op-
eration.

2. State or local codes do not permit vent-free

operation.

3. You prefer vented operation.
If reasons number 1 or 2 above apply to you, you
must permanently open chimney flue damper. You
must install the damper clamp accessory (to order,
see Accessories, page 34). This will insure vented
operation (see Figure 10, page 12). The damper
clamp will keep damper open. Installation instruc-
tions are included with clamp accessory.
See chart below for minimum permanent flue
opening you must provide. Attach damper clamp
so the minimum permanent flue opening will be
maintained at all times.

Chimney

Minimum Permanent

Height (ft.)

Flue Opening (sq. in.)

6' to 15'

39 sq. inches

15' to 30'

29 sq. inches

Area of Various Standard Round Flues

Diameter (inches)

Area (sq. inches)

5

20

6

29

7

39

8

51